EN:This product is only suitable for well-insulated spaces or
occasional use.
DE:Dieser Heizlüfter ist für den Einsatz in gut isolierten
Räumen oder für den kurzzeitigen Einsatz konzipiert.
PL:Grzejnik ten został zaprojektowany do używania w
dobrze ocieplonych pomieszczeniach lub do nieczęstego
wykorzystania.
CZ:Tento ohřívač je určen pro použití v izolovaných
prostorách nebo pro omezené použití.
SK:Toto zariadenie je navrhnuté a vyrobené na používanie v
dobre zateplených miestnostiach a na nie príliš časté
používanie.
HU:A radiátort jól szigetelt helyiségekben való, nem
túlzottan gyakori használatra tervezték.
SL:Grelnik je bil zamišljen za uporabo v dobro ogrevanih
prostorih oz. za redko uporabo.
HR:Grijalica je projektirana za upotrebu u dobro izoliranim
prostorijama ili za rijetku upotrebu.
EL:Η θερμάστρα σχεδιάστηκε για χρήση σε καλά μονωμένα
δωμάτια ή σε χρήση από καιρό σε καιρό.
BG:Този нагревател е проектиран за използване в д
обре термоизолирани помещения и е предвиден з
а по-рядка употреба.
RO:Acest radiator a fost proiectat pentru utilizare în încăperi
bine izolate sau pentru utilizare ocazională.
LT:Šis šildytuvas buvo sukurtas naudoti gerai termiškai
izoliuotose patalpose arba retam naudojimui.
ET:Radiaator on projekteeritud hästiköetud ruumides või
mittesagedaks kasutuseks kasutamiseks.
1
FHM601
1
2
1a
1b
1c
1d
1e
FHM601
2
Model identifier(s):PTC-2011A
Item Symbol Value Unit Item Unit
Nominal heat output Pnom 2,0 kW manual heat charge control, with
integrated thermostat [no]
Minimum heat output
(indicative) Pmin 1,0 kW
manual heat charge control with
room and/or outdoor temperature
feedback
[no]
Maximum continuous
heat output Pmax,c 2,0 kW
electronic heat charge control with
room and/or outdoor temperature
feedback
[no]
fan assisted heat output [no]
At nominal heat output elmax 0,000 kW
At minimum heat
output elmin 0,000 kW single stage heat output and no
room temperature control [no]
In standby mode elSB 0,000 kW Two or more manual stages, no
room temperature control [no]
with mechanic thermostat room
temperature control [yes]
with electronic room temperature
control [no]
electronic room temperature
control plus day timer [no]
electronic room temperature
control plus
Information requirment for the electric local space heaters
Heat output Type of heat input, for electric storage local space
heaters only (select one)
Auxiliary electricity
consumption
Type of heat output/room temperature control (select
one)
Other control options (multiple selections possible)
week timer [no]
room temperature control, with
presence detection [no]
room temperature control, with
open window detection [no]
with distance control option [no]
with adaptive start control [no]
with working time limitation [no]
with black bulb sensor [no]
Contact details
3
IMPORTANT NOTES
Before using this device read the instruction manual and
follow the instructions inside. The manufacturer is not liable
for any damages caused by the misuse of this device due to
inappropriate handling. Please keep this manual for future
reference.
This device is for domestic use only. Do not use for any other
purposes.
The device should only be connected to an socket with values
corresponding to the values on the rating label.
It is necessary to check, if total current consumption of all
devices plugged into the wall outlet does not exceed the fuse
in the circuit.
If you are using an extension cord, make sure that the total
power consumption of the equipment plugged into the
extension cord does not exceed the extension cord power
rating. Extension cords should be arranged in such a way as to
avoid tripping hazards. Do not let cord hang over edge of
counter, or touch any hot surface.
The device is not designed to be controlled via an external
timer, separate remote control, or other equipment that can
turn the device on automatically.
Before maintenance work always disconnect the unit from
the power supply.
When unplugging the power cord from electrical outlet, hold
it by the plug only and remove the plug carefully. Never pull
the cable as it may cause damage to the plug or power cord.
Damage to the power cord or plug can lead to an
electrocution hazard.
Never leave the product connected to the power source
without supervision.
FHM601

Właściciel serwisu: TERG S.A. Ul. Za Dworcem 1D, 77-400 Złotów; Spółka wpisana do Krajowego Rejestru Sądowego w Sądzie Rejonowym w Poznań-Nowe Miasto i Wilda w Poznaniu, IX Wydział Gospodarczy Krajowego Rejestru Sądowego pod nr KRS 0000427063, Kapitał zakładowy: 40 618 750 zł; NIP 767-10-04-218, REGON 570217011; numer rejestrowy BDO: 000135672. Sprzedaż dla firm (B2B): dlabiznesu@me.pl INFOLINIA: 756 756 756