3
About this manual
This manual contains important
information on the safe and proper
installation and commissioning of the
product.
FRANKE reserves the right to make
modications to the product without
prior notice. All information correct at
time of issuance.
Carefully read the user manual
before using the device.
Keep the user manual.
Use the device described in this
user manual only according to the
intended use.
Symbol Meaning
Warning symbol. Warning
against risks of injury.
Action step. Species an
action to be done.
Safety information
The use of a Franke Pro M /
Pro M Connect lter is mandatory
to protect the product against
limescale deposits.
After storage at 0°C, the lter
must rst be stored for 24 hours
at room temperature before it is
installed.
Only cold, potable-quality
water may be used to supply the
system.
All components must be
stored dry within a temperature
limit of -15°C to 45°C (5°F to
113°F).
The system must be sited in a
frost-proof place and be
protected from direct sunlight.
The system must not come in
contact with chemicals, solvents
or other vapours.
Before commissioning the
lter system, the appliance must
be free of limescale.
The lter cartridge must not
be opened or damaged.
Do not use with water that is
microbiologically unsafe or of
unknown quality without
adequate disinfection before or
after the system.
After a longer downtime or
maintenance work rinse the
system thoroughly.
EN
4
Product information
Function
All Franke lters reduce heavy metal
ions like lead, copper and cadmium.
The integrated active carbon block
reduces undesirable cloudiness,
organic impurities, odour and taste
and chlorine residue from the ltered
water. Additionally, the Pro M and Pro
M Connect lters use ion-selective
lter medium to reduce the
carbonate hardness of potable water.
The patented mineral stabilization
allows the use of high blending
levels, ensuring high capacity, stable
pH and best taste.
Technical data
Dimensions
Height 245 mm
Height including
lter head 295 mm
Diameter 95 mm
Weight 0.9 kg
Operating data
Working
pressure 2-8 bar (29-116 psi)
Water
temperature /
Ambient
temperature
4-30°C (39-8F)
Mounting
position horizontal / vertical
Minimum ush
volume (after
rst installation)
2 litres (0.5 US gal)
Flush volume
After 1 week
stagnation 2 litres (0.5 US gal)
After 2 weeks
stagnation 10 litres (3 US gal)
After 8 weeks
stagnation
The lter must be
replaced.
Filter settings and capacity*
Based on the carbonate hardness
level of the water supply, use the
table to identify the lter cartridge
capacity.
* only for Pro M / Pro M Connect
Hardness in °dKH Capacity in litres
<4 3.920
53.220
62.830
72.430
82.130
91.890
10 1.700
11 1.550
12 1.280
13 1.180
14 1.090
15 1.020
16 960
17 900
19 810
21 730
23 670
Default settings: 10°dKH,
1.700 litres capacity
EN
5
Filter operation and replacement
Installation of the lter
The system can be operated either
free standing or wall mounted in a
vertical or horizontal position.
Insert the filter cartridge
into the filter head and turn
counterclockwise.
After first installation the system
must be flushed with a minimum
of 2 litres.
Note: The ush water will be milky or
cloudy at rst. This is due to the
dispersing air and will clear up
quickly.
Installation with external lter head
- see page 42.
Installation with internal lter head
- see page 43.
Replacing the lter
Turn filter clockwise to remove it
from filter head.
Note: During this process, incoming
tap water supply and outgoing
ltered water valves in the lter head
shut o automatically. The system
will expand and a small amount of
expansion water may escape from
the ush hose due to peaks in
pressure. Please keep this in mind
and place a suitable container
underneath the ush hose.
Repeat operations in the chapter
“Installation of the filter”.
Service / Maintenance
Reliable system function can only be
achieved if the lter cartridge is
replaced on a regular basis. The
replacement cycle depends on the
carbonate hardness of the water
supply and the bypass level. We
would recommend replacing the
lter cartridge after 6 months and no
later than 12 months depending on
usage.
Pro M Connect and Clear Water
Connect lters, thanks to the
integrated RFID technology, inform
instantly the system when the lter
needs to be replaced.
EN

Właściciel serwisu: TERG S.A. Ul. Za Dworcem 1D, 77-400 Złotów; Spółka wpisana do Krajowego Rejestru Sądowego w Sądzie Rejonowym w Poznań-Nowe Miasto i Wilda w Poznaniu, IX Wydział Gospodarczy Krajowego Rejestru Sądowego pod nr KRS 0000427063, Kapitał zakładowy: 41 287 500,00 zł; NIP 767-10-04-218, REGON 570217011; numer rejestrowy BDO: 000135672. Sprzedaż dla firm (B2B): dlabiznesu@me.pl INFOLINIA: 756 756 756