Znaleziono w kategoriach:
Laktator BABYONO Nurse Pro 1483

Instrukcja obsługi Laktator BABYONO Nurse Pro 1483

Powrót
EN
PL
BG
CZ
EE
FR
HR
HU
IT
LT
LV
PT
RO
RU
SE
SK
UA
2
16
30
44
58
72
86
100
114
128
142
156
170
184
198
212
226
NURSE PRO 2-Phase electric breast pump
Laktator elektryczny dwufazowy NURSE PRO
Двуфазна електрическа помпа за кърма NURSE PRO
Dvoufázová elektrická odsávačka mléka NURSE PRO
NURSE PRO 2-faasiline elektriline rinnapump
Tire-lait électrique à 2 phases NURSE PRO
Dvofazna električna pumpa za dojke NURSE PRO
NURSE PRO kétfázisú elektromos mellszívó
Tiralatte elettrico bifase NURSE PRO
Dviejų fazių elektrinis pientraukis NURSE PRO
Divfāzu elektriskais krūts piena sūknis NURSE PRO
Bomba de leite elétrica bifásica NURSE PRO
Pompă de sân electrică bifazată NURSE PRO
Молокоотсос электрический двухфазный NURSE PRO
Elektrisk 2-fas bröstpump NURSE PRO
Dvojfázová elektrická odsávačka materského mlieka NURSE PRO
Молоковідсмоктувач електричний двофазний NURSE PRO
Cat. No 1483
2
PRODUCT DESCRIPTION
Thank you for purchase and use LD-202 electric breast bump. pump is electric powered suction device used to express and
collect breast milk from lactating mother. This product follows a baby’s natural nursing rhythm. The unique design can
help you to express breast milk quickly and comfortably. Please read this manual carefully before using stimulation and
expression mode. Press the power button, the breast pump automatically starts up in stimulation mode. This is a single use
product that should not be shared between moms.
Two mode technology of Stimulation and Expression:
This product has stimulation and expression mode. Press the power button, the breast pump automatically starts up in
stimulation mode. If no action is taken during stimulation mode, after two minutes, the pump will automatically change to
the expression mode.
Stimulation mode:
Fast sucking/pumping rhythm to stimulate the milk ejection reex and to start the milk owing.
Expression mode:
Slower sucking/pumping rhythm for gentle and ecient milk removal as quickly as possible.
Intended use:
1. This breast pump is for household use only. As the pump is compact and discrete to use, you can take it with you anywhere,
allowing you to express milk at your own convenience and maintain your milk supply.
2. If your breasts are engorged (painful or swollen), you can express a small amount of milk before or between feeds to ease
the pain and to help your baby latch on more easily.
3. If you are separated from your baby and wish to continue to breastfeed when you are reunited, you should express your
milk regularly to stimulate your milk supply.
SAFETY NOTICE
Explanation of symbols:
EN NURSE PRO
2-Phase electric breast pump
SYMBOL EXPLANATION
Type BF applied part
Caution
Consult Accompanying Documents
Keep Away From Sunlight
Storage and Transportation Temperature Limit: -20
o
C~55
o
C (-4
o
F~131
o
F)
Storage and Transportation Humidity Limit: 15~93%RH
Serial Number
EC REP
European Authorized Representative
Manufacturer
Direct Current
3
6
1. Use the product only for its intended use as described in this manual.
2. Please check that all the parts of breast bump is in before using.
3. Do not use attachments not recommended by the manufacturer.
4. Do not attempt to remove the breastshield from your breast while pumping.
Turn the breastpump o and break the seal between your breast and breastshield with your nger, then
remove breastshield from your breast.
5. Never use the breast pump while you are pregnant, as pumping can induce labor.
6. Inspect all appropriate pump components before each use.
7. Clean and sanitize all parts that come in contact with your breast and breastmilk prior to rst use.
8. Wash all parts that come in contact with your breast and breastmilk after every use.
9. For hygienic reasons, this product is intended for use by a single user.
10. Do not allow children or pets to play with the motor unit, the adapter or accessories.
11. Remove the batteries if they are not going to be used for an extended period of time.
12. Although the breast pump is compliant with applicable EMC directives, it may still be susceptible to excessive emissions
and/or may interfere with other equipment. A consequence can be that the breast pump turns o or goes into error mode.
To prevent interference, keep other electric equipment away from the breast pump during expressing.
13.Do not use the device in the MR environment.
Caution
14
15
16
17
18
2
Q
ãã
6
7
98
10
11
12
5
4
3
2
1
13
UNIT ILLUSTRATION
1
2
3
4
18
7
5
17
9
8
10
12
11
13
14
16
15
1× Seal cover
1× Connection tube
1× Elastic diaphragm
1× Seal seat
4× Seal hoops
1× Breastshield
1× Pump body
2× Valves
4× White membranes
1× Breastmilk bottles
1× Bottle stand
1× Motor unit
1× Plugs
1× Dome cap
1× Nipple
1× Screw ring
1× Lids
1× Power Adaptor
POWER ADAPTER USE ATTENTION POINTS
Use only the power adapter that comes with the product.
Make sure the voltage of the power adapter is compatible with the power source.
This product should never be left unattended when plugged into an electrical outlet.
Always unplug the breast pump immediately after use.
4
STEP 5:
Put the Elastic diaphragm into the seal seat,make sure the
daphragm edge and seal seat edge close tting.Then seal by
the seal cover make it as a sealed isolation assembly.
If there is no „O” - shaped sealing ring on the plug at the
bottom of the sealing seat ,please set the seal hoop into the
groove in the plug position.
STEP 6:
Make one side of c without plug insert into seal cover and
make another side of connection tube insert into motor unit.
Then insert the whole isolation assembly into connector.
STEP 1:
Insert breastshield into the funnel-shaped section of the
pump body
STEP 2:
Please install the white membrane on valve smoothly.
Make sure the white membrane won’t curl up.
STEP 3:
Insert the valve into pump body the from underneath. Push
the valve in as faras possible.
STEP 4:
Screw the pump body clockwise onto the bottle until it is
securely xed.
INSTALLATION INSTRUCTIONS
Product Assembly
Note: Make sure you have cleaned and optionally disinfected the appropriate parts of the breast pump.
After cleaning, follow these steps to assemble your collection units:
Figure 6-1 Figure 6-2
Figure 6-3
Figure 6-4
Figure 5-1 Figure 5-2
Figure 5-3
Figure 5-2
Figure 5-3 Figure 5-4
5
Battery Installation
This product can use 4 AA alkaline batteries as power supply. Please install the battery according to the direction of the
battery polarity shown at the bottom of the unit.
Do not reverse polarity.
Do not mix old and new batteries.
Do not mix alkaline, standard(carbon-zinc) or rechargeable batteries.
Each set of batteries will provide approximately 1.5 hours of pumping time. For battery operation, the motor unit LCD will
display the battery symbol . If the battery symbol ashes, which means the battery remaining is not enough for breast bump
normal work, please replace the batteries.
The Power Adapter
Although the design of the product can be used in the battery inside the unit power adapter, meanwhile, we recommend that
remove the battery before use the power adapter. If you need to use power adapter when you using battery, please shut down
the breast bump then access external power supply and turn on the product. When the external power supply is used, the
battery symbol will not show on the screen. At the same time the external power symbol will light up.
Please don’t insert or pull out the power adapter with wet hand. Please don’t plug the power adapter with the power
supply for a long time.

Właściciel serwisu: TERG S.A. Ul. Za Dworcem 1D, 77-400 Złotów; Spółka wpisana do Krajowego Rejestru Sądowego w Sądzie Rejonowym w Poznań-Nowe Miasto i Wilda w Poznaniu, IX Wydział Gospodarczy Krajowego Rejestru Sądowego pod nr KRS 0000427063, Kapitał zakładowy: 40 618 750 zł; NIP 767-10-04-218, REGON 570217011; numer rejestrowy BDO: 000135672. Sprzedaż dla firm (B2B): dlabiznesu@me.pl INFOLINIA: 756 756 756