GB | Digital Power Meter
Device description
The power consumption metre P5805 (hereinafter referred to as metre) is an electronic
device which measures power consumption and can also calculate and display operating
costs of the measured appliance on agraph. The graph can be set up to display the last 7
days/weeks/months. This function allows the user to reduce power costs and decrease
CO2 emissions.
Specications:
Nominal voltage: 230–240 V~/50 Hz
Nominal current: max. 16 A
Max. load: 3 680 W
Operating voltage: 175–276 V~/50 Hz
Period recorded: 0 sto 9 999 days
Operating temperature: 0–50 °C
Measuring range: 2 to 3 680 W
Power consumption range: 0 kWh to 9 999 kWh
Battery: 2× 1.5 V (LR44/AG13)
Use in normal dry conditions with relative humidity ranging from 20 to 90 %
Connection: First, remove the plastic ring from the battery space at the
rear of the metre, as shown in the picture. The installed
batteries 2× 1.5V (LR44/AG13) are used to power the metre
memory.
Then, connect the metre to a230 V~ power network. Do
not connect any appliance to the metre yet. If the display
of the metre does not show any data or the data is dicult to read, press the „RESET“
button using asharp pointy object such as apen or apencil. Then, the screen will display
all characters as shown on the gure below. This display will remain for ca 3 seconds.
2
3
Display settings:
1. current time setup
1.1 Press and hold the „SET/OK“ button for 3 seconds. You will enter the settings mode
and the clock icon will start blinking. You can change the time values using the buttons
„ENERGY/+“ (increasing values) or „COST/-“ (decreasing values). Pressing the „HISTORY“
button will switch between hours and minutes. Once current time is set, press „SET/OK“.
Switching to 12/24 hour mode
After setting the current time, the metre will work on a24 hour time cycle. If you want
to switch to 12 hour mode, simultaneously hold the „HISTORY“ and „ENERGY/+“ buttons
for 3 seconds. The display will show the AM or PM symbol. AM indicates morning hours,
PM afternoon hours. Set the desired time mode (12/24).
1.2 Total operating time of the connected appliance (TOTAL TIME):
Once the load (input power of the connected appliance) exceeds 2 W, total time will
start recording automatically. You can display the total operating time by pressing the
„COST/-“ button.
1.3 using the „COST/-“ button, the display will show the following, in order:
Total operating time
Total power consumption 0.00–9 999 kWh
Total power costs 0.00–9 999 EUR
4
5
Power costs in tari 1 (0.00 EUR/kWh – 9 999 EUR/kWh)
Tari 1 start time
Power costs in tari 2 (0.00 EUR/kWh – 9 999 EUR/kWh)
Tari 2 start time
CO2 volume in kg: 0.00 – 9 999 kg CO2 /kWh
Total CO2 consumption in kg 0.00 – 9 999 kg
2. Setting power current tari
Keep pressing the „COST/-“ button until you reach the power current tari settings.
4
5
Hold the „SET/OK“ button for 3 seconds. „DUAL TARIFF“ will start blinking. Again press
„SET/OK“ – use the „HISTORY“ button to change the number, then press „ENERGY/+“ or
„COST/-“ to set arange between 0.00 EUR/kWh and 9 999 EUR/kWh; you can move between
numbers using the „HISTORY“ button. Finally, press „SET/OK“ to conrm the set values.
2.1 Setting power current tari 1 time
After setting the tari values, the screen will show „TIME START“
Press the „HISTORY“ button and select which value you want to change. By pressing
„ENERGY/+“ or „COST/-“, you can increase or decrease the values. When you are done,
press „SET/OK“.
2.2 Setting power current tari 2
To set up power current tari 2, proceed as described in points 2 and 2.1
Note:
If dual tari is set, tari 1 will start from the set time and turn o when the set time for
tari 2 comes. Current tari 2 will end the moment tari 1 begins.
3. Overload settings
Hold the „ENERGY/+“ button for 3 seconds; the top left corner of the screen will now
display „OVERLOAD“. Then, using the „HISTORY“ button, move between values and set the
maximum load. The default setting is 3 680 W. You can save the settings by pressing „SET/
OK“. After exceeding the set value, the „OVERLOAD“ sign will start blinking.
4. Setting CO2:
Keep pressing „COST/-“ until you reach the following screen.

Właściciel serwisu: TERG S.A. Ul. Za Dworcem 1D, 77-400 Złotów; Spółka wpisana do Krajowego Rejestru Sądowego w Sądzie Rejonowym w Poznań-Nowe Miasto i Wilda w Poznaniu, IX Wydział Gospodarczy Krajowego Rejestru Sądowego pod nr KRS 0000427063, Kapitał zakładowy: 41 287 500,00 zł; NIP 767-10-04-218, REGON 570217011; numer rejestrowy BDO: 000135672. Sprzedaż dla firm (B2B): dlabiznesu@me.pl INFOLINIA: 756 756 756