Znaleziono w kategoriach:
Zasilacz UPS EATON 3S 550 FR 550VA 330W

Instrukcja obsługi Zasilacz UPS EATON 3S 550 FR 550VA 330W

Wróć
EATON 3S
550/700
www.eaton.com
Installation and
user manual
English - Français
Deutsch - Italiano
Español - Nederlands
Português - Eλληνiκά
Polski - Česky
Solvenčina - Slovensko
Magyar - Türkçe
РУCCКИЙ
Svenka - Suomi
CE compliance contact: Eaton I.F. SAS - 110 rue Blaise Pascal - 38330 Montbonnot St Martin - France
2
Packaging
l Before installing the Eaton 3S,
read the booklet 3 containing the
safety instructions to be respected.
Then follow the instructions given
in this manual 2.
l Avant l'installation de Eaton 3S,
lire le livret 3 qui présente les
consignes de sécurité à respecter.
Suivre ensuite les instructions du
présent manuel 2.
l Vor Installation des Eaton 3S
die im Heft 3 genannten
Sicherheitsvorschriften lesen.
Anschließend die Anweisungen
im vorliegenden Handbuch 2
befolgen.
l Prima dell’installazione del
Eaton 3S, leggere attentamente le
istruzioni di sicurezza riportate sul
libretto 3.
In seguito, attenersi alle istruzioni
riportate sul presente manuale 2.
l Antes de la instalación del
Eaton 3S, leer el manual 3 que
presenta las instrucciones de
seguridad a cumplir.
A continuación, seguir las
instrucciones del presente manual
2.
l Lees voordat u het Eaton 3S
gaat installeren eerst de
veiligheidsinstructies in boekje 3.
Volg daarna de instructies van deze
handleiding 2.
l Antes da instalação do Eaton 3S,
ler o caderno 3 onde constam
as instruções de segurança a
respeitar.
Depois, seguir as instruções do
presente manual 2.
p
3
2
Eaton 3S,
l Przed zainstalowaniem Eaton 3S,
należy przeczytać instrukcję 3,
która zawiera niezbędne zalecenia
bezpieczeństwa.
Następnie należy zapoznać się z
zaleceniami zawartymi w niniejszej
instrukcji 2.
l Před instatací zdroje Eaton 3S
si prostudujte příručku 3 kde
najdete bezpečnostní předpisy,
které je třeba dodržovat.
Dále postupujte podle pokynů
uvedených v příručce 2.
l Pred inštaláciou výpustky si
prečítajte knižku 3, v ktorej sú
uvedené bezpečnostné príkazy,
ktoré je potrebné dodržať. Potom
postupujte podľa pokynov tejto
príručky 2.
l Preden instalirate Eaton 3S,
preberite knjižico 3, v kateri so
varnostna navodila, ki jih je treba
upoštevati.
Nato sledite navodilom tega
priročnika 2.
l Az Eaton 3S telepítése előtt
olvassa el a 3-es könyvet, mely a
betartandó biztonsági előirásokat
tartalmazza. Ezután kövesse a jelen,
2-ös kezikönyv utasításait.
l Eaton 3S tesisatini yapmadan
önce, uyulacakgüvenliktalimatlarini
gösteren 3 sayili kitapçiği
okuyunuz. Dana sonra isbu 2
sayili ei kitabindaki talimatlara
uyunuz.
p
3
2
Eaton 3S,
3
2
Eaton 3S
l Innan installation av Eaton 3S, läs
instruktionsmanualen 3
innehållande
säkerhetsinstruktionerna och
följ sedan dem. Följ sedan
instruktionerna som ges i denna
manual 2.
l Lue nämä ohjeet ennen Eaton 3S
asennusta turvallisuusohjeet 3 ja
käyttöohjeet 2.
Caution!
4
2 3
1
IEC models
Out
In
EATON 3S
550/700
3
Quick start
Out
In
Out
In
B
D
C
E
AFR / DIN IEC
F
Download Software at:
powerquality.eaton.com
Register warranty at:powerquality.eaton.com
4
Battery change
l Warning: take care not to inverse the polarity + (red) and - (black) when connecting the batteries as this will
destroy the device.
Out
In
Out
In
Out
In
a
b
c
e
Out
In
f
d
Technical characteristics
(*) Warning: EATON 3S is a class C2-UPS product. In a domestic environment, these products may cause radio
interference, in which case, the user may be required to take additional measures.
Output cables should not exceed 10 m length.
EATON 3S 550 700
l UPS power 550 VA / 330 W 700 VA / 420 W
l Nominal input voltage 184 V - 264 V, adjustable to 161 V - 284 V
l Input frequency 50/60 Hz (46 - 70 Hz working range)
l Voltage/frequency of battery backup
outlets 6 in battery mode
220 V / 230 V / 240 V ±7 % (50/60 Hz ±1 Hz)
with pseudosinusoidal wave
l Total output current for all outlets 10 A max
l Output current of battery backup outlets 62.4 A max 3.1 A max
l Leakage current 0.5 mA
l Input protection 10 A resettable circuit breaker
l Transfer time 5 ms typical
l Telephone surge protection Tel, ISDN, ADSL, Ethernet
l Sealed lead-acid battery 12 V, 5 Ah 12 V, 7 Ah
l Automatic battery test Once a week
l Average battery life 4 years typical, depending on number of discharge cycles and temperature
l Operating temperature 0 to 40 °C
l Storage temperature -25 °C to +55 °C
l Operating relative humidity 0 to 85 %
l Operating elevation 0 to 2000 m
l Safety standards IEC 62040-1, CE certied
l Electromagnetic compatibility standards IEC 62040-2
l Warranty 2 years
l Dimensions (mm) 335 x 140 x 86 335 x 170 x 86
l Weigth (Kg) 3.3 3.8
5

Właściciel serwisu: TERG S.A. Ul. Za Dworcem 1D, 77-400 Złotów; Spółka wpisana do Krajowego Rejestru Sądowego w Sądzie Rejonowym w Poznań-Nowe Miasto i Wilda w Poznaniu, IX Wydział Gospodarczy Krajowego Rejestru Sądowego pod nr KRS 0000427063, Kapitał zakładowy: 41 287 500,00 zł; NIP 767-10-04-218, REGON 570217011; numer rejestrowy BDO: 000135672. Sprzedaż dla firm (B2B): dlabiznesu@me.pl INFOLINIA: 756 756 756