Odbiornik termostatyczny EMOS OpenTherm P5611OTR

Instrukcja obsługi Odbiornik termostatyczny EMOS OpenTherm P5611OTR

Wróć
2101308000_31-P5611OTR_00_01_WEB 90 × 115 mm
P5611OTR
GB Wireless Receiver
CZ Bezdrátový přijímač
SK Bezdrôtový prijímač
PL Odbiornik bezprzewodowy
HU Vezeték nélküli ve
SI Brezžični sprejemnik
RS|HR|BA|ME Bežični prijamnik
DE Kabelloser Empfänger
UA Бездротовий приймач
RO|MD Receptor fără r
LT Belaidis imtuvas
LV Bezvadu uztvērējs
EE Juhtmevaba vastuvõtja
BG Безжичен приемник
FR Récepteur sans l
IT Ricevitore wireless
ES Receptor inalámbrico
NL Draadloze ontvanger
www.emos.eu
2
111
212
313
414
5 15
6 16
7
17
8
18
9
19
10
20
21
1
3
1.
2.
1 2
3
rear part
zadní část
zadná časť
tylna część
hátulsó rész
zadnji del
stražnji dio
Rückseite
нижня частина
partea din spate
galinė dalis
aizmugure
tagakülg
задна част
partie arrière
parte posteriore
parte trasera
achterste gedeelte
front part
přední část
predná časť
przednia część
elülső rész
sprednji del
prednji dio
Vorderseite
верхня частина
partea frontală
priekinė dalis
priekšpuse
esikülg
предна част
partie avant
parte anteriore
parte delantera
voorste gedeelte
2
3
4
GB | Wireless Receiver
Designed for P5611OT wireless thermostat.
Important
Before rst use, make sure to read carefully the Operating Manual for the thermo-
stat, as well as the manual for the boiler or air-conditioning equipment.
Turn o power before installing the thermostat!
Installation should be carried out by a qualied professional!
Abide by prescribed standards during installation.
You can nd more detailed instructions in the P5611OT thermostat’s manual.
SPECIFICATIONS
Switched load: max. 230 V AC; 16 A for resistive load; 5 A for inductive load
Operating temperature: 0°C to 40°C
Storage temperature: -10°C to 60°C
Unit interconnection: via 868 MHz radio signal, max. 25 mW e.r.p.
Pairing capacity: max. 6 receivers
Power supply: switching unit (receiver) 230 V AC/50 Hz
Dimensions and weight: switching unit: 37 × 115 × 91 mm; 150 g
Control (Portable) Unit
(see Fig. 1)
1 – day of the week
2 – clock
3 – comfort mode
4 – economy mode
5 – manual control
6 – programme preset
7 – comfort/economy mode switch
8 – UP button
9 – change clock
10 – change programme
11 – wireless communication icon
12 – set temperature
13 – frost indication
14 – operation status icon
15 – battery status indication
16 – current room temperature
17 – day prole
18 – DOWN button
19 – change temperature
20 – illuminate screen
21 – RESET
Removing the Rear Cover of the Control Unit
(see Fig. 2)
1. Use a screwdriver to press and hold the inner lock.
2. Remove the front cover.
Switching Unit
(see Fig. 3)
1 – main switch
2 – pairing button
3 – LED indicators
5
LED Indicators
Blue LED indicates the switching unit is powered by 230 V AC. If the unit is not con-
nected to power or if the main switch is in the OFF position, the blue LED is not lit.
Red LED is lit while the heating/air-conditioning system is active.
Main Switch
If the heating/air-conditioning system is not used for an extended period of time, it is
recommended to turn the switching unit o (move the main switch to the OFF position).
INSTALLATION
Pairing the Control Unit with the Switching Unit
Pairing enables transmission of information between the control unit and the switch-
ing unit.
The units pair automatically (self-learning) after pressing the “ID” button.
Attention: When pairing two or more receivers, it is necessary to have pairing
mode activated on all receivers simultaneously!
1. Insert 2× 1.5 V AA batteries into the control unit (make sure polarity of the batteries
is correct). Use alkaline batteries only, not rechargeable ones.
2. Connect the switching unit correctly to the power source, and press and hold the
“ID” button; the top red LED starts ashing.
Long-press the screen illumination button ( ) on the control unit within 10
seconds.
Both units will automatically pair and the icon will be displayed. The red LED
on the switching unit will stop ashing and goes out.
If the pairing of the units fails, the icon will be ashing instead.
Testing Wireless Communication between the Units
1. Use the button to select a temperature a few degrees higher than the current
room temperature.
2. Wait for approximately 10 seconds or press the button.
3. The red LED on the switching unit will light up.
4. If the LED does not light up, move the control unit closer to the switching unit.
Press the button to set a value which is lower than the room temperature – the
receiver must switch o.
5. Repeat steps 1 to 4.
The maximum range between the control and switching unit is 100 m in an open
space. The range may decrease indoors as the signal has to pass through walls
and other obstacles.
6. Press the “RESET” button once the test is complete.

Właściciel serwisu: TERG S.A. Ul. Za Dworcem 1D, 77-400 Złotów; Spółka wpisana do Krajowego Rejestru Sądowego w Sądzie Rejonowym w Poznań-Nowe Miasto i Wilda w Poznaniu, IX Wydział Gospodarczy Krajowego Rejestru Sądowego pod nr KRS 0000427063, Kapitał zakładowy: 41 287 500,00 zł; NIP 767-10-04-218, REGON 570217011; numer rejestrowy BDO: 000135672. Sprzedaż dla firm (B2B): dlabiznesu@me.pl INFOLINIA: 756 756 756