Znaleziono w kategoriach:
Laktator MEDELA Freestyle Hands-Free Technologia 2-Phase Expression

Instrukcja obsługi Laktator MEDELA Freestyle Hands-Free Technologia 2-Phase Expression

Wróć
Freestyle
Hands-free
EN Fold these pages out.
PL Rozłóż te strony.
EN Illustrated items or instruction steps are marked with the figure
and detail number (e.g. ¢2-01).
PL Przedstawione na rysunkach elementy lub instrukcje są oznaczone
liczbą główną inumerem szczełowym (np. ¢2-01).
Medela AG
Lättichstrasse 4b
6340 Baar, Switzerland
www.medela.com
EU Representative:
Medela Medizintechnik GmbH & Co. Handels KG
Georg-Kollmannsberger-Str. 2
85386 Eching, Germany
www.medela.com/support
Poland
Medela Polska Sp. z o.o.
Ul. Wybrzeże Gdyńskie 6D
01-531 Warszawa
Poland
Phone +48 22 865 12 50
Phone/Fax +48 22 865 82 25
info@medela.pl
www.medela.pl
Medela UK Ltd.
Huntsman Drive
Northbank Industrial Park
Irlam, Manchester M44 5EG
United Kingdom
Phone +44 161 776 0400
Fax +44 161 776 0444
info@medela.co.uk
www.medela.co.uk
Medela Australia Pty Ltd
3 Arco Lane,
Heatherton, Vic 3202
Australia
Phone +61 3 9552 8600
Fax +61 3 9552 8699
contact.AU@medela.com
www.medela.com.au
© Medela AG/ref. master doc. 101044096/A
101044533/2022-04/A
Subject to modifications
Model/Type reference: 101043986 Content appearance may vary from pictures
37-70
POLSKI
PL
Laktator elektryczny
Instrukcja obsługi
ENGLISH
3-36
EN
Electric breast pump
Instructions for use
3
3
7-01
3
¢1¢8¢9
3
3
¢4
¢6
7
4. Dry
Allow to air-dry on a clean, unused dish
towel or paper towel. Store the dry parts
in a clean environment.
Do not store parts in an airtight
container/bag if moist. It is important that
all residual moisture dries.
Air-dry
or
7
4. Dry
Allow to air-dry on a clean, unused dish
towel or paper towel. Store the dry parts
in a clean environment.
Do not store parts in an airtight
container/bag if moist. It is important that
all residual moisture dries.
Air-dry
or
10 min
[mm]
17 mm⌀20 mm⌀23 mm
24
21 27
6-02
8-028-01
11D-3
11-5
13
11-4A 11-4B
12
13
...16 ... ... 11D-3
...... ... ... 11D-3
freestyle
freestyle freestyle freestyle freestyle
freestyle freestyle freestyle freestyle freestyle
freestyle freestyle freestyle freestyle freestyle
11-01-3
11-01-1
11-01-4
11-01-5
11-01-2
11- 01
11D-3
11-5
13
11-4A 11-4B
12
13
...16 ... ... 11D-3
...... ... ... 11D-3
freestyle freestyle freestyle freestyle freestyle
freestyle freestyle freestyle freestyle freestyle
freestyle freestyle freestyle freestyle freestyle
11- 02- 3
11- 02-5
11- 02- 4
11- 02-1
11- 02-2
11- 02-7
11- 02- 6
11- 02
¢11
¢5
freestyle
12-01 12-02
12-04 12-05
12-03
¢12
9-01
freestyle
1-03
1-02-1
1-02-2
1-04
1-01-1
1-01
1-01-5
1-01-3
1-01-2
1-01-6
1-01-7
1-01-8
1-01-4
freestyle
2-022-01 2-03
¢2
1-02
6-01
3-023-01
13-04 13-05
¢13
13-0313-01 13-02
¢7
7-07
7-04
7-03
7-02
3. Placing Orioles within your Bra
1. The Orioles pumpset can be worn in a regular
nursing bra. If you find it uncomfortable or painful
during use, try switching to a loser, more stretchy
nursing bra.
2. The Orioles can be used in an vertical or slightly
tilted position for better nipple visibility and milk
ejection. Please note that when the Orioles is worn
at an angle you may fine that the scale is
inaccurate. Your bra will hold the collection cup in
place. Ensure that the tubing is placed outside your
bra so that it is not pinched or bent during use.
3. Make sure you achieve a good seal between
Orioles and your skin.
Ensure that the nipple is centered in the tunnel of
the breast shield.
9
10-01
10-03 10-04
¢10
¢3
mm mm mm
or
10-02
7-05 7-06
freestyle freestyle
freestyle freestyle
3
1. Important safety information
Please read all instructions before using this product.
Keep these instructions for future reference.
Warnings identify all instructions that are important for safety. Failure to observe these
instructions can lead to personal injury or damage to the product.
The following symbols and signal words show the significance of the warnings:
Can lead to serious injury or death.
WARNING
Can lead to minor injury.
CAUTION
Can lead to material damage
(not related to personal injury).
NOTICE
Useful or important information that is not
related to safety.
Information
When using electrical products, especially when children are present, basic safety precautions
must always be followed.
WARNING
To avoid fire, electric shock, or serious burns:
The breast pump should never be left unattended when plugged into a power source.
Never operate an electrical device if it has a damaged cord or plug, if it is not working
properly, if it has been dropped or damaged, or dropped into water. If damage is found,
immediately discontinue use of power adapter and call Medela Customer Service.
Do not use an electrical product that has been exposed to water or other liquids including:
– Do not use while bathing or showering.
– Never place or drop into water or other liquids.
– Do not run water over the breast pump.
If an electrical product has been exposed to water or other liquids, do not touch and if
possible unplug the device from electrical outlet, turn off and contact the manufacturer.
Do not expose the breast pump or battery to excessive temperatures.
Be aware of the risk of USB-C-socket of the pump or battery beeing shortcircuited
by metal objects or fluids.
Only use the supply unit (S010BL*0500200) provided with this appliance.
4
CAUTION
To avoid health risks and reduce the risk of severe injury:
This is a single-user product. Use by more than one person may present a health risk and
voids the warranty.
Do not use the breast pump while operating a moving vehicle.
Pumping may induce labour. Do not pump until after giving birth. If you become pregnant
while breastfeeding or breast pumping, consult with a licensed healthcare professional
before continuing.
If infected with Hepatitis B, Hepatitis C, or Human Immunodeficiency Virus (HIV), pumping
breast milk will not reduce or remove the risk of transmitting the virus to your baby through
your breast milk.
Wash all parts that come into contact with your breast and breast milk after every use.
The tubing poses a risk of strangulation when being played with and small parts may be
swallowed by toddlers.
Close supervision is necessary when the breast pump or accessories are used in the vicinity
of children.
This appliance is not intended for use by persons (including children up to 14 years) with
reduced physical, sensory or mental capabilities, or lack of experience and knowledge,
unless they have been given supervision or instruction concerning use of the appliance
by a person responsible for their safety.
Children must not play with the appliance.
Cleaning and maintenance must not be performed by children without supervision.
CAUTION
To avoid fire or burns:
Make sure the voltage of the power adapter is compatible with the power source.
See chapter 18 for technical specifications.
Always unplug electrical products immediately after use except for when charging.
Do not place or store the product where it can fall into water.
The breast pump and accessories are not heat-resistant. Keep away from heated
surfaces or open flames.
Do not use near flammable materials.
5
CAUTION
To avoid health risks and reduce the risk of injury:
Before each use visually inspect the individual components for cracks, chips, tears,
discoloration or deterioration. In the event that damage to the device is observed,
please discontinue use until the parts have been replaced.
This product cannot be serviced or repaired. Do not repair yourself. Do not modify
the device.
Never use a damaged device. Replace defective or worn parts.
Use the breast pump only for its intended purpose as described in these instructions
for use.
Do not use the breast pump while sleeping or overly drowsy.
If tubing becomes mouldy, discontinue use and replace tubing.
Do not microwave or boil breast milk. Microwaving can cause severe burns to babys
mouth from hot spots that develop in the milk during microwaving (microwaving or boiling
can also change the composition of breast milk).
Clean and sanitise all parts that come into contact with your breast and breast milk prior
to first use.
Only use Medela recommended parts with your breast pump.
If pumping is uncomfortable or causing pain, turn the unit off, break the seal between the
breast and the breast shield with your finger and remove the breast shield from your breast.
While some discomfort may be felt when first using a breast pump, using a breast pump
should not cause pain. If you are unsure about correct breast shield sizing please visit
www.medela.com or see a lactation consultant/breastfeeding specialist who can help
you get a proper fit.
Contact your healthcare professional or breastfeeding specialist if you can express only
minimal or no milk or if expression is painful. See chapter7.1 for more information.
NOTICE
Take appropriate care in handling bottles and components:
Plastic bottles and parts become brittle when frozen and may break when dropped.
Bottles and parts may become damaged if mishandled (e.g., dropped, over-tightened,
or knocked over).
Do not use the breast milk from bottles or components that show signs of damage.

Właściciel serwisu: TERG S.A. Ul. Za Dworcem 1D, 77-400 Złotów; Spółka wpisana do Krajowego Rejestru Sądowego w Sądzie Rejonowym w Poznań-Nowe Miasto i Wilda w Poznaniu, IX Wydział Gospodarczy Krajowego Rejestru Sądowego pod nr KRS 0000427063, Kapitał zakładowy: 41 287 500,00 zł; NIP 767-10-04-218, REGON 570217011; numer rejestrowy BDO: 000135672. Sprzedaż dla firm (B2B): dlabiznesu@me.pl INFOLINIA: 756 756 756