Znaleziono w kategoriach:
Irygator TRUELIFE AquaFloss Station O300 Ozone Biały

Instrukcja obsługi Irygator TRUELIFE AquaFloss Station O300 Ozone Biały

Wróć
AquaFloss Station
O300 Ozone
EN UsEr maNUal
DE BENUtzErhaNDBUch
cz UživatElský maNUál
sk PoUžívatEľský maNUál
Pl iNstrUkcja UżytkowNika
hU haszNálati útmUtató
slo UPoraBNiški PriročNik
hr UPUtE za UPotrEBU
3
3
EN UsEr maNUal
Box contents
TrueLife AquaFloss Station O300 Ozone
3× Standard nozzles, 1× Dental Plaque
nozzle, 1× Orthodontic nozzle,
1× Periodontal nozzle
Battery cover opener
1× AAA battery
Manual and safety instructions
Product descriPtion
7
10
6
7
8
9
3
12
2
4
1
11 5
1. Water reservoir cover
2. Water reservoir
3. Base
4. Display
5. Nozzle
6. Power button
7. Increase power button
8. Decrease power button
9. Oxidation on/o button
10. Storage compartment door
11. Nozzle release button
12. Rubber suction cups
4
Nozzles
Please note: There may be
residual water in the device.
This is distilled water that is
used when testing the device.
instructions for use
Remove all packaging materials before rst use.
If the water osser has been exposed to a low temperature environment during
transport, leave it at room temperature for at least two hours before use.
1. Connect the nozzle to the handle. It will click when correctly inserted.
2. Remove the water reservoir from the base and ll it with water not exceeding
40°C. The capacity of the reservoir is 600 ml. Return the reservoir to the base and
make sure that no water overows.
3. Plug in the water osser.
4. Use the power increase and decrease buttons to set the pressure you want. The
currently set pressure is shown on the display with a choice of 10 levels.
5. Use the oxidation on/o button to choose which water you want to use for clea-
ning. The „O3 Water“ icon will ash on the display for oxidised water and the „Na-
tural Water“ icon for conventional water.
6. Lean over the sink and put the nozzle in your mouth. Aim the nozzle at your teeth
and use the power button to start cleaning.
7. Leave your mouth slightly open to allow water to ow freely from your mouth
into the sink. Direct the water stream at a 90° angle towards the teeth and gums.
Slowly move the water stream around the teeth. Direct the water stream towards
the gums and the spaces between the teeth. If you have braces, you can direct the
water between the joints of the braces.
8. The water osser has a preset automatic cleaning timer of 3 minutes. If you want
to oss your teeth for a longer time, restart with the power button.
9. When you have nished cleaning, switch the device o using the power button.
Open the lid of the water reservoir and pour out the remaining water. Switch the
device on again to empty the water from the pump.
Note: To prevent the spread of bacteria, make sure that no water is left in the device. If
you are not going to use the device for a long period of time, make sure it is thoroughly
dried before storing it.
Standard Periodontal Dental Plaque Orthodontic
5
inserting/rePlacing the nozzle
Insert the nozzle into the opening at the top of the osser. When correctly inserted
you’ll hear a click.
To remove the nozzle from the handle, press and hold the nozzle release button and
pull the nozzle out.
The nozzles can be swivelled 360°.
The box includes the following nozzles:
Standard Jet – used to rinse hard-to-reach areas and places where a conven-
tional toothbrush cannot reach.
Orthodontic Jet – a special orthodontic nozzle designed to clean and rinse
hard-to-reach areas around braces.
Periodontal Jet – directs the stream of water or mouthwash below the gum
line thanks to the tapered silicone end.
Dental Plaque Jet – used for more eective removal of dental plaque with
easier access to aected areas.
Note: Only insert and remove the nozzles when the osser is switched o.
Note: Nozzles are subject to personal hygiene and are not subject to warranty.
rePlacing the Battery in the handle
The handle is powered by an AAA battery. When the controls stop working, it means
the battery is dead and needs to be replaced.
Follow the instructions below:
1. Use the special opener to open the cover on the bottom of the handle.
2. Replace the battery with a new one.
3. Close and secure using the opener again.
We recommend removing the battery from the handle if you are not using the devi-
ce for an extended period of time.
Maintenance
Use only water and neutral detergents for maintenance purposes. Never use caus-
tic or abrasive cleaners as they can damage the equipment. Do not use water at
temperatures above 50°C. Keep the equipment away from high temperatures and
avoid direct sunlight.
1. Base
Remove dirt by wiping it down with a towel or cloth with liquid soap and water. Then
wipe it dry. Do not immerse the device in water.
2. Water reservoir
Wash the reservoir with water and wipe with a dry cloth.
Dry the reservoir thoroughly if you are not going to use it for a long time.

Właściciel serwisu: TERG S.A. Ul. Za Dworcem 1D, 77-400 Złotów; Spółka wpisana do Krajowego Rejestru Sądowego w Sądzie Rejonowym w Poznań-Nowe Miasto i Wilda w Poznaniu, IX Wydział Gospodarczy Krajowego Rejestru Sądowego pod nr KRS 0000427063, Kapitał zakładowy: 41 287 500,00 zł; NIP 767-10-04-218, REGON 570217011; numer rejestrowy BDO: 000135672. Sprzedaż dla firm (B2B): dlabiznesu@me.pl INFOLINIA: 756 756 756