APPLICABLE MODELS:
ASH-18WO/N2C2-EU
Indoor unit model
ASH-18W/N2C2-EU
Outdoor unit model
ASH-18O/N2C2-EU
ASH-09WO/N2C2-EU
Indoor unit model
ASH-09W/N2C2-EU
Outdoor unit model
ASH-09O/N2C2-EU
ASH-24WO/N2C2-EU
Indoor unit model
ASH-24W/N2C2-EU
Outdoor unit model
ASH-24O/N2C2-EU
ASH-12WO/N2C2-EU
Indoor unit model
ASH-12W/N2C2-EU
Outdoor unit model
ASH-12O/N2C2-EU
Table of Contents
Safety Precautions
1
1
3
4
7
14
17
Troubleshooting
Product Overview
How to Use
How to Install
Care & Maintenance
Foreword
English
Safety Precautions
Be sure to establish an earth connection.
Thank you for purchasing our product.
Read this user manual carefully before use to ensure correct usage.
Please retain this user manual for future reference.
Improper use of the product may result in malfunction, accidents, or potential hazards.
This appliance can be used by children aged from 8 years and above and persons with reduced physical,
sensory or mental capabilities or lack of experience and knowledge if they have been given supervision
or instruction concerning use of the appliance in a safe way and understand the hazards involved.
Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by children without supervision.
After reading, keep this manual in a convenient place so that you can refer to it whenever necessary. If
the equipment is transferred to a new user, be sure also to hand over the manual.
Keep this manual where the operator can easily find it.
For safety reasons, the operator must read the following cautions carefully.
Failure to follow these instructions properly
may result in personal injury or loss of life.
WARNING
Foreword
Safety Instructions
This product can only use the power supply indicated on the nameplate. Please use the specified power
cord and do not change it by yourself.
Do not connect the grounding wire of the power supply to a gas tank or water pipe. Insufficient
grounding may result in electric shock.
Make sure that the wiring harness, drainage pipe, and compressor pipe are connected correctly.
Improper connection may cause the air conditioner not to function normally or reduce performance
after some time, or even have problems of water leakage, electrical leakage, refrigerant leakage, electric
shock, or fire accidents.
Use the remote control to turn the product on or off instead of plugging or unplugging the power plug
during daily use. Please turn off the product and unplug the power plug when not in use for a long time.
When the ambient humidity is high, please increase the fan speed or adjust the air guide blade angle to
the maximum using the swing button to prevent water droplets from falling.
Do not install the air conditioner in places where flammable or explosive gases may leak, where the
environment is humid, or where electromagnetic interference is significant. The indoor unit of this air
conditioner is not waterproof, so do not use it in humid environments such as laundry rooms or
bathrooms.
This marking indicates that this product should not be disposed with other household
wastes throughout the EU. To prevent possible harm to the environment or human health
from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse
of material resources. To return your used device, please use the return and collection
systems or contact the retailer where the product was purchased. They can take this
product for environmental safe recycling.
Operator's manual;
operating instructions
Service indicator; This appliance is
filled with R32.
read technical manual
Read operator's
manual
1
•Do not use means to accelerate the defrosting process or to clean, other than those recom-
mended by the manufacturer.
•The appliance shall be stored in a room without continuously operating ignition sources (for
example: open flames, an operating gas appliance or an operating electric heater.
•Do not pierce or burn.
•Be aware that refrigerants may not contain an odour.
Following these basic precautions will reduce the risk of fire, electric shock, injury or death when using
your air conditioner.
The air conditioner must be connected to proper electrical outlet or breaker with the correct electrical
supply. And only the specified power can be used.
Proper grounding must be ensured to reduce the risk of shock and fire.
Do not cut or remove the grounding prong. lf you do not have a three-prong electric receptacle outlet
or breaker in the wall, have a certified electrician install the proper receptacle or breaker. The wall
receptacle or breaker MUST be properly grounded.
Do not use if power cord is frayed or otherwise damaged. Also avoid using it if there are cracks or
abrasion damage along the length, plug or connector.
Do not use an adapter or an extension cord.
Do not block airflow inside or outside the air conditioner with blinds, drapes, protective covers, or
shrubs.
Be careful of sharp edges on the front and rear fins of the unit that could cut and cause serious injury.
Be careful when lifting the air conditioner to install or remove the unit. Always use two or more people
for this.
Always cut off the power of air conditioner before servicing it or moving it.
Some models may not have a plug that matches your wall outlet due to different power standards. If so,
a suitable power adaptor needs to be used, and the regular plug instructions don't apply.
An all-pole disconnection switch having a contact separation of at least 3 mm in all poles should be
connected in fixed wiring.
The appliance shall be installed in accordance with national wiring regulations.
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly
qualified persons in order to avoid a hazard.
WARNING
The air conditioner should be stored in areas with no persistent sources of ignition, such as open flames,
lighted gas appliances, electric heaters that are turned on.
Do not puncture or ignite the air conditioner.
Before servicing or repairing an air conditioner with R32 refrigerant, a safety inspection must be carried
out to ensure that the risk of danger is minimized.
lf the air conditioner leaks refrigerant, please open all doors and windows immediately, keep the room
ventilated, turn off the power, leave the room, and call for repair.
When installing or relocating the air conditioner, be sure to bleed the refrigerant circuit to ensure it is
free of air, and use only the specified refrigerant (R32). The presence of air or other foreign matter in the
refrigerant circuit causes abnormal pressure rise, which may result in equipment damage and even
injury.
Always use a vacuum pump to remove air from the system. Do not use refrigerant in the outdoor unit for
evacuation.
After completing installation, check for refrigerant gas leakage.
Please check the safety signs carefully before installing and using the air conditioner.
Some models use R32 or other flammable refrigerants, which need to be operated and
used in accordance with the instructions for use.
Refrigerant Safety Precautions
When indoor ventilation equipment is used together with indoor heating equipment or gas stoves, it
should be ensured to avoid hypoxic accidents caused by insufficient ventilation.
Do not blow the air from the air conditioner directly to animals or plants; otherwise it may cause
adverse effects.
When cleaning the air conditioner, be sure to turn it off and cut off the power supply, and make sure
that the air conditioner has completely stopped before operating.
Do not poke your fingers or sticks into the exhaust inlet or exhaust outlet of the air conditioner.
Otherwise, it may cause damage to the air conditioner or even personal injury.
Do not place any objects on the outdoor unit and check its mounting brackets frequently. If there is any
damage, repair it in time; otherwise, the outdoor unit may fall and cause injury.
If any abnormality in the air conditioner (such as a burnt smell) is found, turn the air conditioner off, cut
off the power supply immediately, and contact the after-sales service team.
For safety's sake, cut off the power supply before touching the air conditioner.
Do not install the air conditioner in special places such as ships or vehicles.
Please follow the refrigerant charging procedures when a recharge is needed.
2
Cooling Operation
Indoor side DB/WB (℃) Outdoor side DB/WB (℃)
Heating Operation Dry Operation
Working temperature range
Conditions of Use
Outdoor temperature above 52°C
Maximum cooling 32/23
27/-
43/26
24/18Maximum heating
Outdoor temperature below 18°C
Indoor temperature below 21°C
Indoor
temperature
below 18°C
Outdoor temperature above 24°C
Outdoor temperature below -20°C
Indoor temperature above 27°C
The operating temperature range (outdoor temperature) is 18°C to 43°C for cooling mode and -20°C to
24°C for heating mode.
Under the temperature conditions listed in the table below, the air conditioner may automatically enter
the protection mode.
4
Product Overview
Indoor Unit Accessories
Indoor Unit
Outdoor Unit
Remote Control
Connecting Nut
Drainage Hose
Drain Port
Screw Pack
AAA Battery
Warranty Notice
User Manual
Note:
Illustrations of product, accessories, and user interface in the user manual are for reference purposes
only. Actual product and functions may vary due to product enhancements.
Note: DB (Dry Bulb): Ambient temperature; WB (Wet Bulb): Temperature with humidity effects.
Display
3

Właściciel serwisu: TERG S.A. Ul. Za Dworcem 1D, 77-400 Złotów; Spółka wpisana do Krajowego Rejestru Sądowego w Sądzie Rejonowym w Poznań-Nowe Miasto i Wilda w Poznaniu, IX Wydział Gospodarczy Krajowego Rejestru Sądowego pod nr KRS 0000427063, Kapitał zakładowy: 41 687 500,00 zł; NIP 767-10-04-218, REGON 570217011; numer rejestrowy BDO: 000135672. Sprzedaż dla firm (B2B): dlabiznesu@me.pl INFOLINIA: 756 756 756