Product description
5
6
8
1 Power button
2 Scanner
3 LCD display
4 Temperature button
5 Battery cover
6 Protective scanner cap
7 Silent mode switch
8 Guidance light
Made and
printed in China
Certain trademarks used under license from
The Procter & Gamble Company or its aliates.
Patents: https://www.braunhealthcare.com/us_en/patents
Kaz Europe Sàrl
A Helen of Troy Company
Place Chauderon 18
CH-1003 Lausanne
Switzerland
KAZ Hausgeräte GmbH
Kölner Strasse 23
DE-57439 Attendorn - Germany
HOT (UK) LTD
PO Box 5984
Sheeld, S2 9GN - United Kingdom
© 2021, All rights reserved
www.braunhealthcare.com/us_en/patents
0297
23
Thank you for purchasing the Braun No touch + touch thermometer (BNT300). This thermometer is
a high-quality product incorporating the latest technology and tested in accordance with
international standards. With its unique technology, the product can provide a stable, accurate
reading with each measurement. The thermometer performs a self-test every time it is switched on
to always guarantee the accuracy of measurements.
Please read these instructions carefully before using this product and keep the instructions
and the thermometer in a safe place.
Intended use and contraindications
This No touch + touch thermometer is an handheld, battery-powered, infrared thermometer
intended for the intermittent measurement of human body temperature in a home-use
environment on people of all ages, except pre-term and small-for-gestational-age babies, using
the center of the forehead as the measurement site.
These thermometers are not intended for clinical use in a professional environment and are for
home usage only. This thermometer is not intended to interpret hypothermic temperatures.
WARNINGS AND PRECAUTIONS
Keep out of reach of children under 12 years.
Never use the thermometer for purposes other than those it has been intended for. Please follow
the general safety precautions when using on children.
Never immerse the thermometer into water or other liquids (not waterproof). For cleaning and
disinfecting please follow the instructions in the “Care and cleaning section.
Do not store this thermometer in temperature extremes below -25 °C or over 55 °C (below -13 °F or
over 131 °F) or in excessive humidity (above 95% non-condensing relative humidity).
If thermometer is stored in a location that is cooler or warmer than where it is being used, let
it sit in the patient’s room for 10 minutes before taking the measurement.
Do not use the thermometer if there are signs of damage on the scanner or on the thermometer
itself. If damaged, do not attempt to repair the product.
Never scratch the sensor with a sharp object when cleaning.
This thermometer consists of high-quality precision parts. Do not drop the instrument. Protect it
from severe impact and shock. Do not twist the instrument or the measuring sensor.
This thermometer is intended for household use only.
Use of this thermometer is not intended as a substitute for consultation with your doctor.
Temperature elevation may signal a serious illness, especially in neonates and infants, or in adults
who are old, frail, or have a weakened immune system. Please seek professional advice immediately
when there is a temperature elevation and if you are taking temperature on:
Neonates and infants under 3 months (Consult your doctor immediately if the temperature
exceeds 37.4 °C [99.4 °F])
Patients over 60 years of age (Fever may be blunted or absent in older patients)
Patients having diabetes mellitus or a weakened immune system (e.g., HIV positive, cancer
chemotherapy, chronic steroid treatment, splenectomy)
English
Patients who are bedridden (e.g., nursing home patient, stroke, chronic illness, recovering from
surgery)
A transplant patient (e.g., liver, heart, lung, kidney).
Do not allow children to take their temperatures unattended.
Please consult your doctor if you see symptoms such as unexplained irritability, vomiting, diarrhea,
dehydration, changes in appetite or activity, seizure, muscle pain, shivering, sti neck, pain when
urinating, etc., even in the absence of fever.
Even in the absence of fever, those who exhibit a normal temperature may still need to receive
medical attention. People who are on antibiotics, analgesics, or antipyretics should not be assessed
solely on temperature readings to determine the severity of their illness.
Do not modify this equipment without the authorization of the manufacturer.
Why Braun No touch + touch thermometer?
Measurement in under 2 seconds
The innovative infrared technology allows measurement of
touch temperature in under 2 seconds whether you use
the touch or no touch option.
Accurate and reliable
Due to the unique patented technology, the No touch + touch thermometer
captures the heat naturally given o by the forehead to calculate body
temperature value. Get the same professional accuracy whether touching your
child’s forehead or holding up to 2.5 cm away.
Easy to use
The No touch + touch thermometer is non-invasive. A measurement can be
taken even while a child is sleeping.
The No touch + touch thermometer is less threatening to a child than a rectal
thermometer and easier to use than other methods.
Safe and hygienic
No-touch option helps minimize spreading of germs. Safe for use on children
and adults.
How does Braun No touch + touch work?
The Braun No touch + touch thermometer measures infrared energy radiated from the skin at the
center of the forehead area. This captured energy is collected through the sensor and converted to
an oral equivalent temperature value.
The No touch + touch thermometer has been clinically tested and proven to be safe and
accurate when used in accordance with its operating instruction manual.
2 sec
45
Fever guidance feature
Fever guidance helps you to better understand the meaning of your child’s temperature with the
color indicated on the display. The screen displays green if no fever, yellow for fever and a red alert
for a possibly high fever. 10 audible beeps indicate temperatures above 37.4 °C (99.4 °F) to alert the
user that the patient may have a fever.
Color range Reading Meaning
Green ≥ 35.8 – ≤ 37.4 °C
(≥ 96.4 – ≤ 99.4 °F) Normal
Yellow > 37.4 – ≤ 38.5 °C
(> 99.4 – ≤ 101.3 °F) Fever
Red > 38.5 °C
(> 101.3 °F) High fever
NOTE: Backlight remains OFF when below temperature readings are registered:
34.0 ≤ T < 35.8 °C (93.2 ≤ T < 96.4 °F)
How to use your Braun No touch + touch
1. Remove cap
2 Power on
Press and release the power
button once. Backlight will come
on and the start-up sequence
begins.
NOTE: Make sure to remove the
protective scanner cap before
taking a measurement.
When the thermometer is ready and correctly positioned, a horizontal line of dashes (“---”) will
appear on the screen.
0-5 cm
(
0 - 3”
)
High fever
Fever
Normal
Red
Yellow
Green
3. Position
Position thermometer on or up to 2.5 cm away from
the center of the forehead, just between the eyebrows.
For No touch readings, the yellow guidance light will
show you where you are aiming. If the eyebrow area is
covered with hair, sweat or dirt, please clean the area
beforehand to improve the reading accuracy. It is
important to hold the thermometer and the forehead
steady during measurement. Movement will impact
the temperature reading.
Temperature results may vary if positioned in the
wrong location
4. Take temperature
Press the temperature button (you can press and hold the button or press
and release it). When the thermometer is placed correctly, the screen
displays a dashed line animation while it takes a reading. After the
animation sequence (under 2 seconds), the display shows the temperature
reading. The appropriate fever light color is displayed on screen and the
conrmation beep is heard.
If the thermometer is positioned
too far away from the forehead, it
will prompt you to move the
thermometer closer by displaying
diagram and “0-2 cm”. Slowly
move the thermometer toward
the forehead until the horizontal
line animation starts and the temperature reading is displayed.
5. Read temperature
Remove the thermometer and read the temperature. For low
(no backlight) and normal (green backlight) temperature
range, you will hear a single long beep for 2 seconds. For
fever (yellow backlight) and possible high fever (red
backlight) temperature range, you will hear 10 short beeps.
To repeat
Go to step 3.
6. To turn o
Press the power button to turn o. Device will also shut o automatically after 60 seconds of no use.
0 - 2.5 cm
0-5 cm
(
0 - 3”
)
High fever
Fever
Normal
Red
Yellow
Green
0-5 cm
(
0 - 3”
)
High fever
Fever
Normal
Red
Yellow
Green
English
67
Temperature-taking hints
It is important to know each individual’s normal temperature when they are well. This is the only way to
accurately diagnose a fever. Take multiple readings when healthy to determine normal temperature.
A child’s normal temperature can be as high as 37.7 °C (99.9 °F) or as low as 36.1 °C (97.0 °F). Be sure
to note this unit reads 0.5 °C (0.9 °F) lower than a rectal digital measurement.
Patient must be inside for 30 minutes before taking a measurement.
Note: Patient and the thermometer should be in the same ambient temperature for at least
10 minutes.
Always hold the thermometer and the forehead steady when taking a reading. Do not move the
thermometer until you hear the nal beep. Don’t take a measurement while or immediately after
nursing a baby.
Patients should not drink, eat, or be physically active before/while taking the measurement.
Remove hats and wait 10 minutes before taking a measurement.
Before taking a measurement, remove dirt or hair from the forehead area. Wait 10 minutes
after cleaning before taking measurement.
Always take the temperature exactly as directed. Temperature results may vary if positioned in the
wrong location.
For patients measuring their own temperature, it is recommended to use the touch” option
instead of “no touch.
In the following situations it is recommended that three temperatures in the same location be
taken and the highest one taken as the reading:
Newborn infants in the rst 100 days.
Children under three years of age with a compromised immune system and for whom the
presence or absence of fever is critical.
When the user is learning how to use the thermometer for
the rst time until he/she has familiarized himself/herself
with the instrument and obtains consistent readings.
General precautions:
Remove any sweat prior to measuring with a dry cloth.
Avoid any cooling or warming cloths on the forehead for at
least 30 minutes prior to measurement.
Do not take temperature measurements over scar tissue,
open sores or abrasions.
Keep the measurement sensor and lens clean. Avoid directly
touching the sensor or lens.
Always store the thermometer with the protective cap in
place to prevent dirt and scratches from damaging the
device.
Make sure to remove the protective cap before taking a
measurement and to put the cap back on after using the thermometer.
Changing the temperature scale
1. Open battery compartment and remove the batteries.
2. °C / °F switch is accessible in the center of the battery
compartment.
3. Slide switch to °C or °F to set preferred temperature scale.
4. Replace the batteries and close the battery door.
Changing the sound mode
The Braun No touch + touch thermometer allows you to silence
the beeps on the thermometer to avoid waking a sleeping child.
To activate the silence feature, slide the switch to the silent
mode position and take a temperature reading. An icon will
appear on the screen to indicate that the thermometer is in
silent mode.
Calibration
This product has been calibrated at the time of manufacture. If used according to the use
instructions, periodic calibration is not required. This device is not intended as a substitute for
regular check-ups by your doctor, please consult your doctor if you have any doubt about the
temperature reading.
Inquiry
In Europe, any serious incident (e.g. death, life-threatening injury, surgical intervention, ...) that has
occured in relation to this thermometer should be reported to Kaz Europe (see Helen of Troy
Consumer Service Numbers) and to the competent authority of your member state.
REF, LOT and Serial numbers of your product must be provided as they are essential to record and
follow up your inquiry or claim. The LOT and Serial numbers are located in the battery
compartment. The production date is given by the LOT number and can be deciphered as
explained below:
The rst 3 numeric digits in the LOT number represent the day of the year of manufacture. The next
2 numeric digits represent the last two numbers of the calendar year of manufacture and the
letter(s) at the end designates the production site. (E.g.: LOT No.: 12313tav this product was made
on the day 123, year 2013 at production site “tav.)
Guarantee
Please read all instructions before attempting to use this device. Please retain the receipt as proof
of and date of purchase. The receipt must be presented when making any claim within the relevant
guarantee period. Any claim under the guarantee will not be valid without a proof of purchase.
Your device is guaranteed for Two Years (2 Years) from date of purchase.
This guarantee covers defects in materials or workmanship that occur under normal use; defective
devices meeting these criteria will be replaced free of charge.
English

Właściciel serwisu: TERG S.A. Ul. Za Dworcem 1D, 77-400 Złotów; Spółka wpisana do Krajowego Rejestru Sądowego w Sądzie Rejonowym w Poznań-Nowe Miasto i Wilda w Poznaniu, IX Wydział Gospodarczy Krajowego Rejestru Sądowego pod nr KRS 0000427063, Kapitał zakładowy: 40 618 750 zł; NIP 767-10-04-218, REGON 570217011; numer rejestrowy BDO: 000135672. Sprzedaż dla firm (B2B): dlabiznesu@me.pl INFOLINIA: 756 756 756