Znaleziono w kategoriach:
Miernik wilgotności drewna STANLEY 0-77-030

Instrukcja obsługi Miernik wilgotności drewna STANLEY 0-77-030

Wróć
0-77-030
www.STANLEYTOOLS.com 79003406
Moisture Meter
GB
NL
GR
I
FIN
HU
BG
LV
D
DK
CZ
E
NO
SK
RO
LT
F
SE
RU
PT
PL
SI
EE
TR
HR
B
T
STHT77030
ON/SET
B
T
ON/SET
STHT77030
% %
44 2.0
1.8
1.6
1.4
1.2
1.0
0.8
0.6
0.4
0.2
40
35
30
25
20
15
10
6
2
User Manual
GB
Low Battery
Icon
Power
Button
Wood Scale
Temperature
Test Sockets
Cap
Building
Materials
Scale
B
T
STHT77030
ON/SET
B
T
ON/SET
STHT77030
% %
44 2.0
1.8
1.6
1.4
1.2
1.0
0.8
0.6
0.4
0.2
40
35
30
25
20
15
10
6
B
T
STHT77030
ON/SET
B
T
ON/SET
STHT77030
% %
44 2.0
1.8
1.6
1.4
1.2
1.0
0.8
0.6
0.4
0.2
40
35
30
25
20
15
10
6
Figure 1
Electrodes
LCD Display
STANLEY® Moisture Meter
The Stanley Moisture Meter detects
moisture in wood and common building
materials including, but not limited to,
drywall, plaster, concrete and cement
board.
WARNING:
ALWAYS follow all instructions and
warnings included in this operator
manual.
DO NOT splash or immerse the unit in
water.
ALWAYS turn off the product when not
in use.
ALWAYS ensure batteries are inserted
in the correct manner, with the correct
polarity.
DO NOT mix old and new batteries.
Replace all of them at the same time
with new batteries of the same brand
and type.
NEVER intentionally short any battery
terminals.
DO NOT attempt to charge alkaline
batteries.
DO NOT mix battery chemistries.
DO NOT dispose of batteries in re.
ALWAYS remove the batteries if storing
the unit for over a month.
DO NOT dispose of this product with
household waste.
ALWAYS check local codes and properly
dispose of used batteries.
PLEASE RECYCLE in line with local
provisions for the collection and disposal
of electrical and electronic waste.
CAUTION: The electrode pins are
very sharp. Handle instrument carefully.
Keep pins covered when not in use.
3
Operating Instructions
BATTERY:
Open door on back of the unit using
a Philips head screwdriver. Insert 4 new
AAA batteries, ensuring polarity is correct
per the indication on the inside of case.
Replace battery door and Phillips head
screw. When the battery symbol appears
on the LCD screen, it is time to replace
your batteries.
OPERATION:
Remove cap (cap can be stored on
bottom of unit while in use).
Turn the unit on by pressing the power
button once.
Press electrodes into the material to be
tested.
Press carefully, but as deeply as
possible to get good contact.
In wood, take measurements across
the grain (Figure 1).
Take several readings at various
locations to get a better idea of the
general moisture content of the
material.
The unit will auto-hold the moisture
measurement on display for 5 seconds
once the reading has stabilized and pins
are removed from the material being
measured.
The unit will automatically shut off after
approximately 1 minute of not being used/
no measurements.
The unit displays the environment
temperature at the top of the LCD display.
To change between F° & C° simply hold
the power button for about 3 seconds.
VERIFYING UNIT CALIBRATION:
There are 2 pairs of metal test sockets on
the top of the cap, these can be used to
test the moisture meter.
Touch the 2 probes to the 2 metal
contacts marked “T”, the reading on the
wood scale should be 19% ±1.
Now touch the 2 probes to the 2 metal
contacts marked “B”, all indication bars
should blink on the LCD display.
If the moisture meter operates as
mentioned above, the unit is working
properly.
SPECIFICATIONS:
Display LCD with dual
measuring scale
Range, Wood 6 – 44%
Range, Building
Materials
0.2 – 2.0%
Auto Power Off 1 minute
IP degree: IP20
Operating
Temperature 0°C – 40°C
(32°F – 104°F)
Storage
Temperature
-10°C - 50°C
Operating Humidity 80% Max Relative
Humidity
Battery 4x AAA (1.5 volt)
Accessories Carry pouch w/belt
loop
4
User Manual
GB
Material Conversion Table:
The following table contains specic conversions for some common materials. All
values listed are in material % moisture.
Display Beech Sqruce Concrete Plaster Cement Aerated
Reading /Oak/Birch C20/C25 Screed Concrete
44 29 33.6 1.6 2.3 1.8 9.5
42 27.4 32 1.6 2.1 1.8 9
40 27.1 31.4 1.6 2.1 1.8 8.8
38 25.3 29.4 1.6 2 1.8 8
36 24.1 28 1.5 1.9 1.7 7.7
34 22.9 26.7 1.5 1.8 1.7 7.2
32 21.9 25.6 1.5 1.6 1.7 6.6
30 20.8 24.3 1.4 1.4 1.6 5.7
28 20.3 23.8 1.4 1.4 1.6 5.6
26 19.4 22.8 1.4 1.3 1.6 5.1
24 18.7 22 1.4 1.2 1.6 4.8
22 17.7 20.9 1.3 1 1.5 4.6
20 15.8 18.7 1.3 0.8 1.4 4.1
18 14.6 17.4 1.3 0.6 1.4 3.7
16 11.9 14.2 1.2 0.3 1.2 3
14 9.2 11.3 1.2 0.2 1.1 2.7
12 7.4 9.2 1.1 0.1 1.1 2.4
10 6.7 8.4 1.1 0.1 1.1 2.3
8 5.6 7.3 1.1 0.1 1 2.2
= Dry = Wet
5
1-YEAR WARRANTY
Stanley warrants its electronic measuring
tools against deciencies in materials and
/ or workmanship for one year from date of
purchase.
Decient products will be repaired or replaced,
at Stanley’s option, if sent together with proof
of purchase to:
Stanley Black & Decker
210 Bath Road
Slough, Berkshire SL1 3YD
UK
This Warranty does not cover deciencies
caused by accidental damage, wear and
tear, use other than in accordance with
the manufacturer’s instructions or repair or
alteration of this product not authorised by
Stanley.
Repair or replacement under this Warranty
does not affect the expiry date of the Warranty.
To the extent permitted by law, Stanley shall
not be liable under this Warranty for indirect or
consequential loss resulting from deciencies
in this product.
This Warranty may not be varied without the
authorisation of Stanley.
This Warranty does not affect the statutory
rights of consumer purchasers of this product.
This Warranty shall be governed by and
construed in accordance with the laws of the
country sold where in and Stanley and the
purchaser each irrevocably agrees to submit
to the exclusive jurisdiction of the courts of that
country over any claim or matter arising under
or in connection with this Warranty.
Calibration and care are not covered by
warranty.
NOTE:
The customer is responsible for the correct
use and care of the instrument. Moreover,
the customer is completely responsible for
periodically checking the accuracy of the laser
unit, and therefore for the calibration of the
instrument.
Subject to change without notice

Właściciel serwisu: TERG S.A. Ul. Za Dworcem 1D, 77-400 Złotów; Spółka wpisana do Krajowego Rejestru Sądowego w Sądzie Rejonowym w Poznań-Nowe Miasto i Wilda w Poznaniu, IX Wydział Gospodarczy Krajowego Rejestru Sądowego pod nr KRS 0000427063, Kapitał zakładowy: 41 287 500,00 zł; NIP 767-10-04-218, REGON 570217011; numer rejestrowy BDO: 000135672. Sprzedaż dla firm (B2B): dlabiznesu@me.pl INFOLINIA: 756 756 756