GB | Thermostat
The P5604 thermostat is designed for controlling heating and air-con-
ditioning systems.
Important
Before the rst use, make sure to carefully read the Operating
Manual for the thermostat, as well as the boiler or air-conditioning
equipment.
Turn o power supply before installing the thermostat!
Installation should be carried out by a qualied person!
During installation, follow applicable standards.
Technical specications:
Switched load: max. 230 V AC; 8 A for resistive load; 2 A for inductive
load
Clock accuracy: ±60 seconds/month
Temperature measurement: 0 °C to 40 °C with 0.1 °C resolution
accuracy ±1 °C at 20 °C
Temperature setting: 5 °C to 35 °C in 0.5 °C increments
Temperature dierential: 0.2 °C
Operating temperature: 0 °C to 40 °C
Storage temperature: -20 °C to 60 °C
Power supply: 2× 1.5 V AAA batteries
Accessories: 2 screws, 2 wall plugs
Dimensions and weight: 30 × 120 × 75 mm; 125 g
Display Description (See Fig. 1)
1 – Operating mode
2 – Cooling mode
3 – Low battery indicator
4 – Current set temperature
5 – Room temperature
6 – Heating mode
Procedure for Removing the Front of the Thermostat (See Fig. 2)
Display Backlighting
Pressing the control wheel activates display backlighting for 10 seconds.
INSTALLATION
Warning:
Before replacing the thermostat, disconnect the heating/air-conditioning
system from the main power in your at. This will prevent potential injury
by electric current.
4
Thermostat Installation
The rear of the thermostat carries 4 openings for mounting onto a wall.
Use the enclosed screws and wall plugs to mount the thermostat.
Wiring Diagram
Voltage connection diagram for connecting thermostat P5604 to
a boiler with "NO" outlet:
Max. 230 V 8(2) A 230 V~N
NL
L
NO NCCOM
Heating device requiring
230 V power supply,
e.g. central heating pump. Thermostat
* When connecting a cooling device to the thermostat, connect the "L"
phase conductor to the "NC" terminal.
Zero-voltage connection diagram for connecting thermostat P5604
to a boiler with "NO" outlet:
Max. 230 V 8(2) A
NO
COM
NO NCCOM
Heating device requiring
zero-voltage contact,
e.g. gas boiler. Thermostat
Putting into Operation
1. Remove the front portion of the thermostat and insert 2× 1.5 V AAA
batteries. Use alkaline batteries only, not rechargeable ones.
2. Replace the front of the thermostat.
3. The thermostat now has an active display and is operational.
If the thermostat is not working properly, please check the polarity of the
batteries, whether they are suciently charged, or reset the thermostat
by removing the batteries.
Choosing Operating Mode (Heating, Cooling, Anti-Freeze
Temperature)
1. Press and hold the control wheel for 5 seconds to enter mode
settings.
2. Turn the control wheel to select one of the following modes:
5
a. HEAT (heating system)
b. OFF (anti-freeze temperature of 7 °C)
c. COOL (cooling system)
3. Press the control wheel to conrm your selection.
Room Temperature Calibration
Press and hold the control wheel for 5 seconds until the setting mode
indicator starts ashing on the screen.
Press and hold the control wheel again for 5 seconds until the temperature
calibration value starts ashing on the screen.
Use the wheel to set the temperature value of choice (-3.0 °C to 3.0 °C,
in 0.5 °C steps) and conrm by pressing the wheel.
Room temperature calibration is used if, for example, the thermostat
shows 21 °C but you want it to show 20 °C. In that case, the calibration
value should be set to -1 °C.
Upkeep and Maintenance
The product is designed to provide trouble-free service for many years if
used properly. Here are some tips for proper operation:
Read the manual carefully before using this product.
Do not expose the product to direct sunlight, extreme cold and
humidity, and sudden changes in temperature. This would reduce
accuracy of detection.
Do not place the product in locations prone to vibration and shocks
– these may cause damage.
Do not expose the product to excessive force, impacts, dust, high
temperatures or humidity – these may cause malfunction, shorter
battery life, damage to batteries and deformation of plastic parts.
Do not expose the product to rain or high humidity, dropping or
splashing water.
Do not place any open ame sources on the product, e.g. a lit
candle, etc.
Do not place the product to places with inadequate air ow.
Do not insert any objects in the product vents.
Do not tamper with the internal electric circuits of the product – doing
so may damage the product and will automatically void the warranty.
The product should only be repaired by a qualied professional.
To clean the product, use a slightly moistened soft cloth. Do not use
solvents or cleaning agents – they could scratch the plastic parts
and cause corrosion of the electric circuits.
Do not immerse the product in water or other liquids.
In the event of damage or defect of the product, do not perform any
repairs by yourself. Have it repaired in the shop where you bought it.

Właściciel serwisu: TERG S.A. Ul. Za Dworcem 1D, 77-400 Złotów; Spółka wpisana do Krajowego Rejestru Sądowego w Sądzie Rejonowym w Poznań-Nowe Miasto i Wilda w Poznaniu, IX Wydział Gospodarczy Krajowego Rejestru Sądowego pod nr KRS 0000427063, Kapitał zakładowy: 41 287 500,00 zł; NIP 767-10-04-218, REGON 570217011; numer rejestrowy BDO: 000135672. Sprzedaż dla firm (B2B): dlabiznesu@me.pl INFOLINIA: 756 756 756