Znaleziono w kategoriach:
Ciśnieniomierz MICROLIFE BP B1 Classic Biały

Instrukcja obsługi Ciśnieniomierz MICROLIFE BP B1 Classic Biały

Wróć
IB BP B1 Classic EN-PL 2123
Revision date: 2023-04-24
BPB1 Classic
Blood Pressure Monitor
EN 1
B1 Classic
Blood Pressure Monitor
PL 9
CHDE Polska S.A.
Biesiadna 7, 35-304 Rzeszów
Tel. (0-17) 229-37-89,
Fax. (0-17) 230-21-14
E-mail: biuro.rzeszow@chde.pl
BDO 000046780
Microlife Corporation
9F, 431, RuiGuang Road, NeiHu
Taipei 11492, Taiwan, China
www.microlife.com
Microlife UAB
P. Lukšio g. 32,
08222 Vilnius
Lithuania
13
2
4
56
7
8
9
Microlife BP B1 Classic Microlife BP B1 ClassicGuarantee Card
Name of Purchaser / Imię i nazwisko nabywcy
Serial Number / Numer seryjny
Date of Purchase / Data zakupu
Specialist Dealer / Przedstawiciel
1Microlife BP B1 Classic EN
Display
Intended use:
This oscillometric blood pressure monitor is intended for
measuring non-invasive blood pressure in people aged 12 years
or older.
Dear Customer,
This device was developed in collaboration with physicians and
clinical tests carried out prove its measurement accuracy to be of
a very high standard.*
If you have any questions, problems or want to order spare parts
please contact your local Microlife-Customer Service. Your dealer
or pharmacy will be able to give you the address of the Microlife
dealer in your country. Alternatively, visit the internet at
Microlife BP B1 Classic EN
1ON/OFF button
2Display
3M-button (memory)
4Time button
5Cuff socket
6Mains Adapter Socket
7Battery compartment
8Cuff
9Cuff connector
AT Cuff tube
AK Systolic value
AL Diastolic value
AM Pulse rate
AN Battery display
AO Traffic light indicator
AP Stored value
AQ Pulse indicator
AR Cuff fit check
-A: Suboptimal cuff fit
-B: Arm movement indicator «ERR 2»
-C: Cuff pressure check «ERR 3»
AS Cuff signal indicator «ERR 1»
BT Irregular heartbeat (IHB) symbol
BK Date/Time
Read the important information in these
instructions for use before using this
device. Follow the instructions for use for
your safety and keep it for future reference.
Type BF applied part
Keep dry
Manufacturer
Batteries and electronic devices must be
disposed of in accordance with the locally
applicable regulations, not with domestic
waste.
Authorized representative
in the European Community
Catalogue number
Serial number
(YYYY-MM-DD-SSSSS;
year-month-day-serial number)
Caution
Humidity limitation
Temperature limitation
Medical device
Keep away from children of age 0 - 3
CE Marking of Conformity
S
N
N
2
www.microlife.com where you will find a wealth of invaluable infor-
mation on our products.
Stay healthy – Microlife AG!
* This device uses the same measuring technology as the award
winning «BP 3BTO-A» model tested according to the British and
Irish Hypertension Society (BIHS) protocol.
Table of contents
1. Important facts about blood pressure and
self-measurement
2. Using the device for the first time
Inserting the batteries
Setting the date and time
Selecting the correct cuff
3. Checklist for taking a reliable measurement
4. Taking a blood pressure measurement
Manual inflation
How not to store a reading
How do I evaluate my blood pressure
Appearance of the irregular heartbeat (IHB) symbol
5. Data memory
Viewing the stored values
Clearing all values
6. Battery indicator and battery change
Low battery
Flat battery - replacement
Which batteries and which procedure?
7. Using a mains adapter
8. Error Messages
9. Safety, care, accuracy test and disposal
Device care
Cleaning the cuff
Accuracy test
Disposal
10. Guarantee
11. Technical Specifications
1. Important facts about blood pressure and
self-measurement
Blood pressure is the pressure of the blood flowing in the
arteries generated by the pumping of the heart. Two values, the
systolic (upper) value and the diastolic (lower) value, are
always measured.
The device indicates the pulse rate (the number of times the
heart beats in a minute).
Permanently high blood pressure values can damage your
health and must be treated by your doctor!
Always discuss your values with your doctor and tell them if you
have noticed anything unusual or feel unsure. Never rely on
single blood pressure readings.
There are several causes of excessively high blood pressure
values. Your doctor will explain them in more detail and offer
treatment where appropriate.
Under no circumstances should you alter the dosages of
drugs or initiate a treatment without consulting your
doctor.
Depending on physical exertion and condition, blood pressure
is subject to wide fluctuations as the day progresses. You
should therefore take your measurements in the same
quiet conditions and when you feel relaxed! Take at least
two readings every time (in the morning: before taking medica-
tions and eating / in the evening: before going to bed, bathing
or taking medication) and average the measurements.
It is quite normal for two measurements taken in quick succes-
sion to produce significantly different results.
Deviations between measurements taken by your doctor or in
the pharmacy and those taken at home are quite normal, as
these situations are completely different.
Several measurements provide much more reliable
information about your blood pressure than just one single
measurement.
Leave a small break of 5 minutes between two measurements.
If you are pregnant, you should monitor your blood pressure
regularly as it can change drastically during this time.
If you suffer from a cardiac arrhythmia consult with your doctor
before using the device. See also chapter «Appearance of the
irregular heartbeat (IHB) symbol» of this user manual.
The pulse display is not suitable for checking the
frequency of heart pacemakers!
3Microlife BP B1 Classic EN
2. Using the device for the first time
Inserting the batteries
After you have unpacked your device, first insert the batteries. The
battery compartment 7 is on the bottom of the device. Insert the
batteries (4 x 1.5 V, size AAA), thereby observing the indicated
polarity.
Setting the date and time
1. After the new batteries are fitted, the year number flashes in the
display. You can set the year by pressing the M-button 3. To
confirm and then set the month, press the time button 4.
2. Press the M-button to set the month. Press the time button to
confirm and then set the day.
3. Follow the instructions above to set the day, hour and minutes.
4. Once you have set the minutes and pressed the time button, the
date and time are set and the time is displayed.
5. If you want to change the date and time, press and hold the time
button for approx. 3 seconds until the year number starts to
flash. Now you can enter the new values as described above.
Selecting the correct cuff
Microlife offers different cuff sizes. Select the cuff size to match the
circumference of your upper arms (measured by close fitting in the
centre of the upper arm).
Contact your local Microlife Service if the enclosed cuff 8 does
not fit.
Connect the cuff to the device by inserting the cuff connector 9
into the cuff socket 5 as far as it will go.
3. Checklist for taking a reliable measurement
Avoid activity, eating or smoking immediately before the
measurement.
Sit down on a back-supported chair and relax for 5 minutes.
Keep your feet flat on the floor and do not cross your legs.
Always measure on the same arm (normally left). It is
recommended that doctors perform double arm measurements
on a patients first visit in order to determine which arm to
measure in the future. The arm with the higher blood pressure
should be measured.
Remove close-fitting garments from the upper arm. To avoid
constriction, shirt sleeves should not be rolled up - they do not
interfere with the cuff if they are laid flat.
Always ensure that the correct cuff size is used
(marking on the cuff).
Fit the cuff closely, but not too tight.
Make sure that the cuff is positioned 1-2 cm above the
elbow.
The artery mark on the cuff must lie over the artery which
runs down the inner side of the arm.
Support your arm so it is relaxed.
Ensure that the cuff is at the same height as your heart.
4. Taking a blood pressure measurement
1. Press the ON/OFF button 1 to start the measurement.
2. The cuff will now pump up automatically. Relax, do not move
and do not tense your arm muscles until the measurement
result is displayed. Breathe normally and do not talk.
3. The cuff fit check AR on the display indicates that the cuff is
perfectly placed. If the icon AR-A appears, the cuff is fitted
suboptimally, but it is still ok to measure.
4. When the correct pressure is reached, the pumping stops and
the pressure falls gradually. If the required pressure was not
reached, the device will automatically pump some more air into
the cuff.
5. During the measurement, the pulse indicator AQ flashes in the
display.
6. The result, comprising the systolic AK and the diastolic AL blood
pressure and the pulse rate AM are displayed. Note also the
explanations on further display symbols in this booklet.
7. When the device has finished measuring, remove the cuff.
8. Switch off the device. (The monitor does switch off automati-
cally after approx. 1 min.).
Cuff size for circumference of upper arm
M 22 - 32 cm
M - L 22 - 42 cm
Pre-shaped cuffs are optionally available.
Only use Microlife cuffs.
This device is not compatible with other Microlife cuff sizes
except M and M-L.

Właściciel serwisu: TERG S.A. Ul. Za Dworcem 1D, 77-400 Złotów; Spółka wpisana do Krajowego Rejestru Sądowego w Sądzie Rejonowym w Poznań-Nowe Miasto i Wilda w Poznaniu, IX Wydział Gospodarczy Krajowego Rejestru Sądowego pod nr KRS 0000427063, Kapitał zakładowy: 41 287 500,00 zł; NIP 767-10-04-218, REGON 570217011; numer rejestrowy BDO: 000135672. Sprzedaż dla firm (B2B): dlabiznesu@me.pl INFOLINIA: 756 756 756