Znaleziono w kategoriach:
Inhalator siateczkowy MICROLIFE NEB900 Mesh

Instrukcja obsługi Inhalator siateczkowy MICROLIFE NEB900 Mesh

Wróć
NEB 900 EN-PL 2625
Revision Date: 2025-06-13
3
6
17
8
9
AT
1
2
4
5
-A
1-C
CHDE Polska S.A.
Biesiadna 7, 35-304 Rzeszów
Tel. (0-17) 229-37-89
Fax. (0-17) 230-21-14
E-mail: biuro.rzeszow@chde.pl
BDO 000046780
Distributor
Microlife AG
Espenstrasse 139
9443 Widnau / Switzerland
www.microlife.com
Shenzhen Bi-rich Medical Devices Co., Ltd
The 1st Building of No. 10, Xinqiao GangZai Road,
Xinqiao Street, Bao’An District,
518125 Shenzhen City, Guangdong Province, P.R. China
Phone: +86 755 27464589
www.bi-rich.cn
SUNGO Europe B.V.
Fascinatio Boulevard 522, Unit 1.7,
2909VA Capelle aan den IJssel, The Netherlands
Email: ec.rep@sungogroup.com
1639
Importer
Microlife UAB
P. Lukšio g. 32
08222 Vilnius, Lithuania
www.microlife.com
EUREP@microlife.lt
NEB 900
Rechargeable mesh nebuliser
EN
PL
1
11
Microlife NEB 900
Name of Purchaser / Imię i nazwisko nabywcy
Serial Number / Numer seryjny
Date of Purchase / Data zakupu
Specialist Dealer / Przedstawiciel
AK
AM
AL AN AO
1-B
Please keep lled guarantee card and invoice; should guarantee service be required, contact the dealer from where the product was purchased /
Prosimy zachować wypełnioną kartę gwarancyjną i dowód sprzedaży; w przypadku konieczności skorzystania z serwisu gwarancyjnego, należy skontaktować się ze sprzedawcą,
u którego zakupiono produkt lub bezpośrednio z serwisem.
Microlife NEB 900 Microlife NEB 900 Guarantee Card Microlife NEB 900
1Microlife NEB 900 EN
Microlife NEB 900 EN
1Nebulising head
-A: Cover, -B: Lock, -C: Metal mesh
2Electrodes
3Main unit
4ON/OFF button
5Indicator light
6USB-C socket
7Mouthpiece
8Child face mask
9Adult face mask
AT USB-C cable
AK Nebulising head opening button
AL Opening the nebulising head
AM Filling the nebulising head
AN Connecting the mouthpiece
AO Connecting the mask
This product is subject to European
Directive 2012/19/EU on waste electrical
and electronic equipment and is marked
accordingly. Never dispose of electronic
devices with household waste. Please seek
out information about the local regulations
with regard to the correct disposal of
electrical and electronic products. Correct
disposal helps to protect the environment
and human health.
Read the instructions carefully
before using this device.
Type BF applied part
Class II equipment
Serial number
Reference number
S
NN
2
Dear Customer,
This mesh nebuliser is intended for inhalation therapy for
asthma, chronic bronchitis, and other respiratory illnesses.
If you have any questions, problems or want to order spare
parts please contact your local Microlife-Customer Service.
Your dealer or pharmacy will be able to give you the
address of the Microlife dealer in your country. Alterna-
tively, visit the internet at www.microlife.com where you will
find a wealth of invaluable information on our products.
Retain instructions in a safe place for future reference.
Stay healthy – Microlife Corporation!
Manufacturer
Protected against solid foreign objects of
12.5 mm Ø and greater. Protected against
vertically falling water drops when
enclosure tilted up to 15°.
Authorized representative
in the European Community
Medical device
Importer
Distributor
Caution
Single patient
multiple use (for accessories only)
Humidity limitation for operating
and storage
IP22
Temperature limitation for operating
or storage
Ambient pressure limitation
Unique Device Identifier
CE Marking of Conformity
1639
3Microlife NEB 900 EN
Table of contents
1. Important safety instructions
2. Preparation before use
3. Using the device for the first time
4. Cleaning and disinfecting
Cleaning
Disinfecting
5. Maintenance, care and service
6. Malfunctions and actions to take
7. Guarantee
8. Technical specifications
1. Important safety instructions
Follow instructions for use. This document provides
important product operation and safety information
regarding this device. Please read this document
thoroughly before using the device and keep for future
reference.
This device may only be used for the purposes
described in these instructions. The manufacturer
cannot be held liable for damage caused by incorrect
application.
Never touch the metal mesh in the nebulising head
with your hands or foreign objects.
This device should only be used with original
accessories as shown in these instructions.
This device comprises sensitive components and
must be treated with caution. Observe the storage
and operating conditions described in the
«Technical specifications» section.
Only use the medication prescribed for you by your
doctor and follow your doctor's instructions with regard
to dosage, duration and frequency of the therapy.
Not intended for use in an oxygen rich environment, for
use with flammable agents, nor flammable anaesthetics.
The USB-C cable is for recharging only, the adapter
must comply with IEC 60601-1 standard requirements.
Do not use in dusty or dark places.
Do not keep the medicine in the liquid cup for a long time
or carry it.
Do not use this device near high frequency
electromagnetic transmitters. Electromagnetic interfer-
ence exceeding the requirements of IEC 60601-1may
affect the performance of nebuliser.

Właściciel serwisu: TERG S.A. Ul. Za Dworcem 1D, 77-400 Złotów; Spółka wpisana do Krajowego Rejestru Sądowego w Sądzie Rejonowym w Poznań-Nowe Miasto i Wilda w Poznaniu, IX Wydział Gospodarczy Krajowego Rejestru Sądowego pod nr KRS 0000427063, Kapitał zakładowy: 41 287 500,00 zł; NIP 767-10-04-218, REGON 570217011; numer rejestrowy BDO: 000135672. Sprzedaż dla firm (B2B): dlabiznesu@me.pl INFOLINIA: 756 756 756