Znaleziono w kategoriach:
Termometr BRAUN Thermoscan 7+ Connect IRT6575

Instrukcja obsługi Termometr BRAUN Thermoscan 7+ Connect IRT6575

Wróć
IRT6575
ThermoScan® 7+ connect
Ear thermometer
1
Certain trademarks used under license from The Procter & Gamble Company or its
aliates.
ThermoScan®, ExacTemp®, and Age Precision™ are trademarks of
Helen of Troy Limited and/or its aliates.
The Bluetooth® word mark and logos are registered trademarks owned by
Bluetooth SIG, Inc., and any use of such marks is under license.
App Store is a service mark of Apple Inc., registered in the U.S. and other countries.
Google Play and the Google Play logo are trademarks of Google Inc.
Kaz Europe Sàrl
A Helen of Troy Company
Q-Center, Chaux 4
CH-1030 Bussigny - Switzerland
© 2023, All rights reserved. www.BraunHealthcare.com/uk_en/
Patents: www.braunhealthcare.com/us_en/patents Made in Mexico
GB
English . . . . . . . . . . . . . . . . 2
DE
Deutsch . . . . . . . . . . . . . . 11
ES
Español . . . . . . . . . . . . . . 20
FR
Français . . . . . . . . . . . . . . 29
IT
Italiano . . . . . . . . . . . . . . . 39
NL
Nederlands . . . . . . . . . . . 48
PL
Polski . . . . . . . . . . . . . . . . 56
SA
ةيبرعلا ةغللا . . . . . . . . . . . . . 75
SE
Svenska . . . . . . . . . . . . . . 76
11
1
P/N: A006397R2
27SEP23
32
5
10
4
9
6
7a7b
8
IRT6575NWE
2 3
English
Product description (see page 1)
1 Disposable Hygiene cap (a box of 20 is supplied + 1 already installed ) LF40/LF20
2 Probe tip
3 Probe
4 ExacTemp® Light
5 Hygiene cap ejector
6 Display
7a Age Precision™ Technology button 7b Night mode button
8 Power button
9 Temperature button
10 Battery door
11 Protective case
Intended use and contraindications
The Braun ThermoScan® Ear thermometer is intended to be used by home users for intermittent measurement of the
body temperature of patients having ages ranging from normal weight (full term) new-born to geriatric adult. The
thermometer is reusable. The Braun Hygiene cap is a single use device and is intended to maintain accuracy of
measurement, hygiene and prevent cross-contamination.
This product is not intended to diagnose any disease but is a useful screening tool for temperature.
This thermometer is not intended for clinical use in a professional environment and is for home usage only. The Age
Precision™ Technology feature is not intended for pre-term babies or small-for-gestational age babies. This
thermometer is not intended to interpret hypothermic temperatures. Do not allow children under 12 to take their
temperatures unattended.
Use of the IRT6575 is not intended as a substitute for consultation with your physician.
Warnings and Precautions
Please consult your physician if you see symptoms such as unexplained irritability, vomiting, diarrhea, dehydration,
changes in appetite or activity, seizure, muscle pain, shivering, sti neck, pain when urinating, etc. in spite of any colour
of the background light or absence of fever.
Please consult your physician if the thermometer shows elevated temperature (yellow or red background lights).
The operating ambient temperature range for this thermometer is 10 40 °C (50 104 °F). Do not expose the
thermometer to extreme temperatures (below -25 °C / -13 °F or over 55 °C / 131 °F) or excessive humidity (>95% RH).
This thermometer must only be used with genuine Braun ThermoScan disposable Hygiene caps (LF 40).
To avoid inaccurate measurements ALWAYS use this thermometer with a new, clean Hygiene cap attached.
If the thermometer is accidentally used without a Hygiene cap attached, clean the lens (see «Care and cleaning»
section). Keep Hygiene caps out of reach of children.
DO NOT modify this equipment without authorization of the manufacturer.
Parents/guardians should call the pediatrician upon noticing any unusual sign(s) or symptom(s).
For example, a child who exhibits irritability, vomiting, diarrhea, dehydration, seizure, changes in appetite or activity,
even in the absence of fever, or who exhibits a low temperature, may still need to receive medical attention.
Children who are on antibiotics, analgesics, or antipyretics should not be assessed solely on temperature readings to
determine the severity of their illness.
Temperature elevation as indicated by Age Precision™ Technology may signal a serious illness, especially in adults who
are old, frail, have a weakened immune system, or neonates and infants. Please seek professional advice immediately
when there is a temperature elevation and if you are taking temperature on:
neonates and infants under 3 months (consult your doctor immediately if the temperature exceeds 37.4 °C or 99.4 °F)
Individuals over 60 years of age
Individuals having diabetes mellitus or a weakened immune system (e.g., HIV positive, cancer chemotherapy,
chronic steroid treatment, splenectomy)
Individuals who are bedridden (e.g., nursing home patient, stroke, chronic illness, surgical recovery)
a transplant recipient (e.g., liver, heart, lung, kidney)
Fever may be blunted or even absent in elderly patients.
This thermometer contains small parts that can be swallowed or produce a choking hazard to children. Always keep the
thermometer out of childrens reach.
Age Precision™ Technology
Clinical research shows the denition of fever changes as newborns grow into children and children grow into adults1.
Select the appropriate age setting, take a temperature, and the display will glow green, yellow, or red to indicate
whether the temperature is in a normal, fever, or high fever range, respectively.
1 Herzog L, Phillips S. Addressing Concerns About Fever. Clinical Pediatrics. 2011; 50(#5): 383-390.
Pairing to your smart device
Scan the QR code and download the Braun Family Care™ app.
Follow the in-app instructions to pair your ThermoScan 7+ connect to your smart device.
1. Make sure the device is turned o. Press and hold the Power button until the screen turns blue
and the Bluetooth icon and the letters “bt ash. Flashing will continue until the device
connects to the app.
2. When the thermometer successfully pairs to your smart device, the screen will turn green and
the Bluetooth icon and letters “bt will stop ashing. The thermometer will turn o after 3
seconds.
3. If there is a problem pairing to your smart device, the thermometer will show the error screen.
4 5
English
Temperature-taking hints
Replace disposable Hygiene cap (single use device) with every use to
maintain accuracy, hygiene and to prevent cross-contamination. Earwax
and dirt on the tip of the Hygiene cap, even in a microscopic layer, can
create an obstacle between the sensor and the infrared heat emitted by the
ear and impact the accuracy of the measurement.
External factors like poor probe placement, used or dirty Hygiene cap may
inuence ear temperature measurements.
In clinical studies, precision and accuracy of ear thermometer measurement has been shown to be inuenced by
variability in user technique. Correct probe placement is essential for accurate measurements.
Temperature in right and left ear differs, always compare measurements from the same ear. The natural
physiological dierence may reach 0.2 °C. In the absence of confounding factors, in high-risk population (like infants or
immunodepressed people) use the highest of the two to interpret the patient’s condition.
In the following cases, wait 20 minutes prior to taking a temperature: extreme changes in room temperature, hearing
aid, lying on a pillow. Use the untreated ear if ear drops or other medications have been placed in the ear canal.
How to use your ThermoScan® 7+ connect
1. Remove the thermometer from protective case
2. Power on
Press and release the power button once. Backlight will come on and the start-up sequence begins.. Then the
last temperature taken will be displayed for 5 seconds.
3. Place a new Hygiene cap
The Hygiene cap indicator will blink to signal one is needed.
To achieve accurate measurements, make sure a new, clean Hygiene cap
(LF40/LF20 accessory) is in place before each measurement.
Attach a new Hygiene cap by pushing the thermometer probe straight
into the Hygiene cap inside the box and then pulling out. Hygiene cap
helps protect against cross contamination and promote accurate
readings. Accuracy can be impacted if Hygiene cap is reused.
Note: The Braun ThermoScan® will not work unless a Hygiene cap is attached.
4. Select age range
Select age with Age Precision™ Technology button . Press button to toggle through each
age group.
NOTE: You must select an age in order to take a measurement.
The thermometer is ready to take a temperature.
0-3 Mos >3-36 Mos >36 Mos –
adult
0-3 Months 3-36 Months 36 Months-
adult
To set a preferred age range (locking an age setting):
To save a preferred age range, so that it will be automatically selected when the thermometer is turned ON, follow these
steps:
a. Make sure the thermometer is OFF .
b. Press and hold the power button and Age Precision™ Technology button for
4 seconds. The unit will turn on, displaying a blue backlight and the 3 age range icons will ash.
c. Press the Age Precision™ Technology button. The age range selected will ash. Press the Age Precision™ button
until your desired age range is ashing on the display.
d. Once the desired age range is selected, stop pressing the button and wait 3 seconds.
Default will be set on the device until the batteries are removed and then put back in.
5. Position correctly
Fully insert the thermometer probe into the ear
canal and point it towards the ear canal; make sure
the IRT is pointed toward the ear drum and not the
canal walls.
6. Take temperature
Once positioned correctly, press and release the temperature button . ExacTemp® Stability
Indicator light will pulse while temperature measurement is in progress. The light will remain
solid for 3 seconds to indicate that a successful temperature reading has been achieved.
NOTE: If the probe has been properly inserted into the ear canal during the measurement, a
long beep will sound to signal the completed measurement.
If the probe has not been constantly placed in a stable position in the ear canal, a sequence of
short beeps will sound, the ExacTemp Stability Indicator light will go out and the display will
show an error message (ERROR + position error animated icon = position error).
See «Errors and troubleshooting» section for more information.
7. Read temperature
The conrmation beep indicates that an accurate temperature measurement has been taken. The result is shown on
the display. Temperature reading displayed is an equivalent of oral temperature.
Probe Cover
Probe Cover
Probe Cover
Probe Cover
Age range Green
Normal temperature
Yellow
Fever
Red
High fever
0-3 Months ≥35.8 – ≤37.4 °C
(≥96.4 – ≤99.4 °F)
>37.4 °C
(>99.4 °F)
3-36 Months ≥35.4 – ≤37.6 °C
(≥95.7 – ≤99.6 °F)
>37.6 – ≤38.5 °C
(>99.6 – ≤101.3 °F)
>38.5 °C
(>101.3 °F)
36 Months
- adult ≥35.4 – ≤37.7 °C
(≥95.7 – ≤99.9 °F)
>37.7 – ≤39.4 °C
(>99.9 – ≤103.0 °F)
>39.4 °C
(>103.0 °F)
6 7
English
8. To turn off
For the next measurement, press Eject button to remove, and discard
used Hygiene cap the user will place a new hygiene cap when the next
temperature taking is performed.
NOTE: Defaults to last age setting used if you do not change.
The Braun ThermoScan® Ear thermometer turns o automatically after
60 seconds of inactivity. The thermometer can also be turned o by
pressing the Power button .
The display will briey ash OFF and it will go blank.
Night mode
Night mode is entered by pressing the night mode button. Secondary press of night mode button
turns night mode o - both sound on and ashlight o. The night mode remains on until the
thermometer enters sleep mode through time out or power button press. When the thermometer
is turned back on it will enter normal mode.
In night mode, all audible beeps are muted, the Night mode icon is displayed on the screen and
ashlight will turn on.
At completion of the measurement the ashlight will ash twice and stay on afterwards. Night
mode will stay on until night mode button is pressed or the device is turned o.
How to illuminate the display
The thermometer includes a convenient night light to illuminate the display in a dim
environment.
The light will turn on when you press any button. It will stay on until the thermometer is inactive
for up to 15 seconds even after temperature is taken.
Last reading recall
The previous measurement will be displayed during start up.
After this, the previous measurement will be
displayed in the upper right-hand corner of the
display with an ‘M’ next to it.
The memory in the upper right corner will update to the new reading with the rst button press
after the reading is completed.
How to change temperature between °C and °F
Your Braun ThermoScan® is shipped with the Celsius (°C) temperature scale activated. If you wish to switch to
Fahrenheit (°F) and/or back from Fahrenheit to Celsius, proceed as follows:
1. Make sure the thermometer is turned o.
2. Press and hold the Power button and temperature button . After about 3 seconds the
display will show this sequence: °F / SET / °C / SET.
3. Release the Power button and temperature button , when the desired temperature scale
is shown. There will be a short beep to conrm the new setting, then the thermometer is
turned o automatically.
Errors and troubleshooting
Error message Situation Solution
No Hygiene cap is attached. Attach new, clean Hygiene cap.
The thermometer probe was not positioned
securely in the ear.
An accurate measurement
was not possible.
ERROR + position error animated icon
Take care that the positioning of the probe is correct
and remains stable.
Replace Hygiene cap and reposition.
Press Start button to begin a new measurement
temperature.
Ambient temperature is not within
the allowed operating range
(10 – 40 °C or 50 – 104 °F).
Allow the thermometer to remain for
30 minutes in a room where
the temperature is between 10 and 40 °C
or 50 and 104 °F .
Temperature taken is not within
typical human temperature range
(34 – 42.2 °C or 93.2 – 108 °F).
HI = too high
LO = too low
Make sure the probe tip and lens are clean and a
new, clean Hygiene cap is attached. Make sure the
thermometer is properly inserted. Then, take a new
temperature.
System error – self-check display ashes
continuously and will not be followed by
the ready beep and the ready symbol.
If error persists,
If error still persists,
Wait 1 minute until the thermometer turns o
automatically, then turn on again.
... reset the thermometer by removing the batteries
and putting them back in.
... please contact the Service Centre.
Battery is low, but thermometer will still
operate correctly. Insert new batteries.
Battery is too low to take correct
temperature measurement. Insert new batteries.
System error without messages or
completely dead batteries Insert new batteries. If the error persists, call
customer service.
Unsuccessful connection. Check issue in the app for more details.

Właściciel serwisu: TERG S.A. Ul. Za Dworcem 1D, 77-400 Złotów; Spółka wpisana do Krajowego Rejestru Sądowego w Sądzie Rejonowym w Poznań-Nowe Miasto i Wilda w Poznaniu, IX Wydział Gospodarczy Krajowego Rejestru Sądowego pod nr KRS 0000427063, Kapitał zakładowy: 41 287 500,00 zł; NIP 767-10-04-218, REGON 570217011; numer rejestrowy BDO: 000135672. Sprzedaż dla firm (B2B): dlabiznesu@me.pl INFOLINIA: 756 756 756