Znaleziono w kategoriach:
Stacja pogody HAMA EWS-200 Czarny

Instrukcja obsługi Stacja pogody HAMA EWS-200 Czarny

Wróć
00
186310
EWS-200
Weather Station
Wetterstation
E
F
D
GB
I
PL
H
NL
Operating Instructions
Bedienungsanleitung
Mode d‘emploi
Instrucciones de uso
Gebruiksaanwijzing
Istruzioni per l‘uso
Instrukcja obsługi
Használati útmutató
Manual de utilizare
Návod k použití
Návod na použitie
Manual de instruções
Bruksanvisning
Руководство по эксплуатации
Работна инструкция
Οδηγίες χρήσης
Käyttöohje
RO
CZ
SK
P
S
RUS
BG
GR
FIN
A
B
30
31
33
32
29
1 10
2
4
3
9
11
13
15
19
12
17
2120
14
16
18
5
7
6
8
22 23 24 25 26 27
28
2
Controls and Displays
A Base station
1. Alarm symbol
2. Battery symbol (base station)
3. Summer time
4. Weather forecast symbol
5. Room temperature
6. Comfort range
7. Channel display
8. Outdoor temperature
9. Radio symbol
10. Time
11. Day
12. Month
13. Weekday
14. Moon phase
15. Room temperature trend
16. Room humidity
17. Measuring station radio symbol
18. Outdoor humidity
19. Outdoor temperature trend
20. Outdoor temperature alarm
21. Battery symbol (measuring station)
22. MODE button
= settings/conrm the setting/alarm setting
23. UP button
= increase the current setting/activate or deactivate manual
radio signal reception
24. DOWN/MEM button
= reduces the current setting/accessing the saved
maximum/minimum values
25. CH button
= channel selection/manual search for a signal from the
measuring station
26. ALERT button
= setting/activating/deactivating the outdoor temperature
alarm
27. SNZ/LIGHT button
= stops the alarm/activates the backlight (approx. 10
seconds)
28. Battery compartment
B Measuring station
29. Display (on front side)
= Displays temperature, humidity and current channel.
30. LED indicator (on front side)
= Flashes when signals are transmitted.
31. Opening for wall mounting
32. Set the transmission CHANNEL (1-3)
= Input channel for the weather station. Set the channel
before inserting the batteries.
33. Battery compartment
= Unit requires 2 pcs. UM-4 or AAA 1.5V batteries.
1. Explanation of Warning Symbols and Notes
Warning
This symbol is used to indicate safety instructions or to draw
your attention to specic hazards and risks.
Note
This symbol is used to indicate additional information or
important notes.
2. Package Contents
EWS-200 weather station
(base station for indoors/measuring station for outdoors)
4 AAA batteries
These operating instructions
3. Safety Notes
The product is intended for private, non-commercial use only.
Do not operate the product outside the power limits given in
the specications.
Do not use the product in moist environments and avoid
splashes.
Do not use the product in the immediate vicinity of heaters or
other heat sources or in direct sunlight.
Do not use the product in areas where the use of electronic
devices is not permitted.
Only connect the product to a socket that has been approved
for the device. The socket must be installed close to the
product and easily accessible.
Do not drop the product and do not expose it to any major
shocks.
Do not open the device or continue to operate it if it becomes
damaged.
Do not attempt to service or repair the product yourself. Leave
any and all service work to qualied experts.
Keep the packaging material out of the reach of children due
to the risk of suffocation.
Dispose of packaging material immediately according to
locally applicable regulations.
Do not modify the product in any way. Doing so voids the
warranty.
Use the product for its intended purpose only.
GOperating instruction
3
Warning Batteries
When inserting batteries, note the correct polarity (+ and
- markings) and insert the batteries accordingly. Failure to
do so could result in the batteries leaking or exploding.
Only use batteries (or rechargeable batteries) that match
the specied type.
Before you insert the batteries, clean the battery contacts
and the polar contacts.
Do not allow children to change batteries without
supervision.
Do not mix old and new batteries or batteries of a
different type or make.
Remove the batteries from products that are not being
used for an extended period (unless these are being kept
ready for an emergency).
Do not short-circuit batteries.
Do not charge batteries.
Do not throw batteries in a re.
Keep batteries out of the reach of children.
Never open, damage or swallow batteries or allow
them to enter the environment. They can contain toxic,
environmentally harmful heavy metals.
Immediately remove and dispose of dead batteries from
the product.
Avoid storing, charging or using the device in extreme
temperatures and extremely low atmospheric pressure (for
example, at high altitudes).
4. Getting Started
4.1. Measuring station
Open the battery compartment cover.
Set the desired channel (32) with the switch. If you are using
only one transmitter, please leave the selection at „1“.
Insert 2 new UM-4 or „AAA 1.5V batteries observing correct
polarity.
Close the battery compartment cover and set the unit in the
desired location.
Note
Before use, ensure you insert the batteries in the measuring
station rst and then in the base station.
4.2. Base station
Open the battery compartment (28) and insert two AAA
batteries with the correct polarity. Close the battery
compartment.
5. Installation
Note Installation
We recommend initially placing the base and measuring
stations in the intended locations without installing them
and making all the settings described in 6. Operation
to do.
Only install the stations once the appropriate settings have
been made and a stable wireless connection is established.
Note
The wireless transmission range between the measuring
and base stations is up to 30 m in open spaces.
Before installation, ensure that wireless transmission will
not be disrupted by interference or obstacles like buildings,
trees, vehicles, high-voltage lines, etc.
Before the nal installation, ensure that there is sucient
reception between the intended installation locations.
When installing the measuring station, ensure that it is
protected from direct sunlight and rain.
The international standard height for measuring air
temperature is 1.25 m (4 ft) above ground.
Warning
Buy special or suitable installation material from a
specialised dealer for wall-mounting.
Ensure that no faulty or damaged parts are installed.
Never apply force during installation. This could damage
the product.
Before installation, ensure that the chosen wall is suitable
for the weight to be mounted, and make sure that there
are no electrical wires, water, gas or other lines at the
installation site on the wall.
Do not mount the product above locations where persons
might linger.
5.1. Base station
Use the base to position the base station on a level surface.
5.2. Measuring station
You can also position the measuring station on a level
outdoor surface.
We recommend installing the measuring station securely on
an outdoor wall using the opening (31).
Install an anchor, screw, nail, etc. in the wall of your choice.
Hang up the base/measuring station using the opening
intended for this purpose.

Właściciel serwisu: TERG S.A. Ul. Za Dworcem 1D, 77-400 Złotów; Spółka wpisana do Krajowego Rejestru Sądowego w Sądzie Rejonowym w Poznań-Nowe Miasto i Wilda w Poznaniu, IX Wydział Gospodarczy Krajowego Rejestru Sądowego pod nr KRS 0000427063, Kapitał zakładowy: 41 287 500,00 zł; NIP 767-10-04-218, REGON 570217011; numer rejestrowy BDO: 000135672. Sprzedaż dla firm (B2B): dlabiznesu@me.pl INFOLINIA: 756 756 756